Series AQTIA Air Quality Test Instruments Kits

Air Quality Test Instruments Kits AQTIA Combines the UHH2 Universal Handheld with Compatible Probes

AQTIA Combines the UHH2 Universal Handheld with Compatible Probes

THE SERIES AQTIA AIR QUALITY TEST INSTRUMENTS combine the versatile Model UHH2 handheld base with various compatible probes and modules. The versatile combination provides a line of instruments capable of streamlining a technician’s everyday testing by combining all into one product and using Bluetooth SIG, Inc. wireless technology for ease of use.

Product Applications

  • Building commissioning
  • Building balancing
  • Testing HVAC equipment performance
UHH2 SPECIFICATIONS
Display: 4.3" QHD Gorilla glass, 960x540.
Wireless Distance: 50' (15 m) or greater.
Response Time: 1 s.
Temperature Limits: Operating: -4 to 140°F (-20 to 60°C); Storage: -40 to 176°F (-40 to 80°C).
Humidity Limits: 5 to 95% RH.
Power Requirements: 2000mAh lithium ion battery, installed functional, non-replaceable.
Memory: RAM 1G & ROM 4G.
Operating System: Android® 4.2.2.
CPU: MTK6589W Quad Core 1.2 GHz.
Enclosure Rating: IP68.
Weight: 15.9 oz (450 g).
Agency Approvals: CE.

 

AP2 THERMO-ANEMOMETER PROBE SPECIFICATIONS
Service: Dry, clean air.
Temperature Limits: Process: -20 to 200°F (-29 to 93°C); Ambient: -20 to 140°F (-29 to 60°C); Battery Charging: 32 to 113°F (0 to 45°C).
Range: Air Velocity: 0 to 6000 FPM (0 to 30 m/s); Volumetric Air: 999,999 in selected flow units; Temperature: -40 to 212°F (-40 to 100°C).
Accuracy: Air Velocity: ±3% FS within temperature range of 40 to 90°F (4 to 32°C); Temperature: ±0.5°F (±0.28°C).
Response Time: 1 s.
Probe Length: 8" (203 mm) insertion.
Power Requirements: 3.7 V YT562447 Lithium ion battery, installed functional, user replaceable.
Maximum Wireless Distance: 50' (15 m).
Handle Enclosure: Thermoplastic elastomer over polycarbonate.
Supplied With: Wrist strap.
Weight: 11.2 oz (331.22 g).
Agency Approvals: CE (not while charging), FCC compliant.

 

RP2 THERMO-HYGROMETER PROBE SPECIFICATIONS
Service: Clean air.
Temperature Limits: Process: -4 to 140°F (-20 to 60°C); Ambient: 5 to 125°F (-15 to 51°C); Battery Charging: 32 to 113°F (0 to 45°C).
Range: RH: 0 to 100% (non-condensing); Temperature: -22 to 140°F (-30 to 60°C).
Accuracy: RH: ±2% @ 25°C (10 to 90% RH); ±4% (0 to 10, 90 to 100% RH); Temperature: ±0.54°F @ 77°F (±0.3°C @ 25°C).
Response Time: 1.5 s.
Probe Length: 8" (203 mm) insertion.
Power Requirements: 3.7 V YT562447 Lithium ion battery, installed functional, user replaceable.
Maximum Wireless Distance: 50' (15 m).
Handle Enclosure: Thermoplastic elastomer over polycarbonate.
Supplied With: Wrist strap.
Weight: 11.2 oz (331.22 g).
Agency Approvals: CE (not while charging), RoHS, FCC compliant.

 

VP2 VANE THERMO-ANEMOMETER PROBE SPECIFICATIONS
Service: Clean air.
Temperature Limits: Process: -4 to 140°F (-20 to 60°C); Ambient: 5 to 125°F (-15 to 51°C).
Range: Air Velocity: 50 to 5000 fpm (0.25 to 25 m/s); Temperature: -22 to 140°F (-30 to 60°C); Relative Humidity: 0 to 100% RH; Air Volume: 999,999 in selected units.
Accuracy: Air Velocity: 0.25 to 10 m/s: ±1.5% of reading ±20 fpm (±0.1 m/s); 10 to 20 m/s: 1.5% of reading ±40 fpm (±0.2 m/s); 20 to 25 m/s: ±1.5% of reading ±60 fpm (±0.3 m/s); Temperature: ±0.54°F @ 77°F (±0.3°C @ 25°C); Relative Humidity: ±2% @ 77°F (25°C) (10 to 90% RH); ±4% (0 to 10% and 90 to 100%).
Response Time: Air Velocity: 1 s; Temperature: 1.5 s; Relative Humidity: 1.5 s; Air Volume: 1 s.
Probe Length: 8" (203 mm) insertion.
Power Requirements: 3.7 V YT562447 Lithium ion battery, installed functional, user replaceable.
Battery Charging Limits: 32 to 113°F (0 to 45°C).
Maximum Wireless Distance: 50' (15 m).
Vane Material: Anondized aluminum.
Handle Enclosure: Thermoplastic elastomer over polycarbonate.
Supplied With: Wrist strap.
Weight: 13.6 oz (402.20 g).
Agency Approvals: CE (not while charging), RoHS, FCC compliant.

 

WDPM SPECIFICATIONS
Service: Non-corrosive dry gases.
Wetted Materials: Consult factory.
Accuracy: ±0.5% FS span @ 25°C (includes non linearity, hysteresis, and non repeatability).
Pressure Limits: See model chart on catalog page.
Engineering Units: Pressure: in w.c., ft w.c., in Hg, psi, OzSl, mm w.c., cm w.c., mBar, Pa, hPa, and kPa; Velocity: fpm, mph, kn, m/s, m/h, k/h, and fps; Flow: cfm, gpm, gph, gpd, m3/s, m3/h, lps, lpm, and lph.
Temperature Limits: Compensated: 32 to 140°F (0 to 60°C); Process/Ambient: 14 to 140°F (-10 to 60°C).
Thermal Effects: ±0.01% FS/°F (±0.02% FS/°C).
Battery Charging Limits: 32 to 113°F (0 to 45°C).
Power Requirements: 3.7 V YT562447 lithium ion battery, installed functionally, user replaceable.
Wireless Distance: At least 50' (15 m).
Connections: Two barbed connections for use with 1/8" (3.18 mm) or 3/16" (4.76 mm) ID tubing.
Weight: 2.5 oz (70.87 g).
Agency Approvals: CE with CE approved charger, RoHS, FCC.
  • Rugged IP68 housing withstands 1.5 meter drop test