Series 3100D Explosion-proof Differential Pressure Transmitter

Explosion-proof Differential Pressure Transmitter
HART® Communication, Push Button Configuration, Rangeability (100:1)

HART® Communication, Push Button Configuration, Rangeability (100:1)

The Mercoid® Series 3100D Smart Pressure Transmitter is a microprocessor-based high performance transmitter, which has flexible pressure calibration, push button configuration, and programmable using HART® Communication. The Series 3100D is capable of being configured for differential pressure or level applications with the zero and span buttons. A field calibrator is not required for configuration. The transmitter software compensates for thermal effects, improving performance. EEPROM stores configuration settings and stores sensor correction coefficients in the event of shutdowns or power loss. The Series 3100D is FM or ATEX approved for use in hazardous (classified) locations. The 100:1 rangeability allows the smart transmitter to be configured to fit any application.

Product Applications

  • Flow measurement
  • Level monitoring
  • Filter or pump differential pressure
  • Critical process monitoring
More Information
Model Chart
EXAMPLE 3100D  1 FM 1 LEC S2  A1  00  H   Series 3100D-1-FM-1-1-LECS2A100H2-X-X, Explosion Proof DP Transmitter, range 0.302-6.0" w.c., FM Approval, 1/2" npt female, 2 extended diaphragm seals capillary type, 2" mounting flange 316L, ANSI Class 150, no extension length, Hastelloy C-276 diaphrapm wetted parts, DC silicon 200
SERIES 3100D                           Explosion-Proof Differential Pressure Transmitter
RANGE   1
2
3
4
5
6
7
                        0 - 6.0" w.c. 
0 - 30" w.c. 
0 - 150" w.c. 
0 - 750" w.c. 
0 - 100 psig  
0 - 300 psig  
0 - 1000 psig  
APPROVAL RATING     FM
ATEX
WP
                      FM Approval
ATEX Approved
General Purpose NEMA 4X/IP66  (SST Housing only)
PROCESS CONNECTIONS       1
                    1/4" Female NPT
Diaphragm Seal 
ELECTRICAL CONNECTION                           1/2" Female NPT
DIAPHRAGM SEAL TYPE           LEC
LED
LEH
LEL
LFC
LFD
LFH
LFL
                2 Extended Diaphragm Seals Capillary Type
1 Extended Diaphragm Seals Direct Mount High Side
1 Extended Diaphragm Seals Capillary Type High Side
1 Extended Diaphragm Seals Capillary Type Low Side
2 Flush Diaphragm Seals Capillary Type
1 Flush Diaphragm Seals Direct Mount High Side
1 Flush Diaphragm Seals Capillary Type High Side
1 Flush Diaphragm Seals Capillary Type Low Side
MOUNTING FLANGE             S2
S3 
              2" (50mm) 316L Stainless Steel
3" (80mm) 316L Stainless Steel
MOUNTING FLANGE RATING               A1
A2
D1
D2
J1
J2
            ANSI CLASS 150
ANSI CLASS 300
DIN PN 10/16  
DIN PN 25/40  
JIS 10K       
JIS 20K               
EXTENSION LENGTH                 00
05
10
15 
          No Extension Standard Option for Flush Mount
2" (50mm)
4" (100mm)
6" (150mm) 
WETTED PARTS                   H
P
S
T
        Hastelloy C-276 Diaphragm
PTFE and 316L Stainless Steel Diaphragm
316L Stainless Steel Diaphragm
Tantallum Diaphragm
FILL FLUID                     2       D.C. Silicon 200 (-40-400° F) 
CAPILLARY LENGTH HIGH SIDE              
 
        X     Capillary length 0-20 feet (whole numbers only) 
CAPILLARY LENGTH LOW SIDE                           Capillary length 0-20 feet 
OPTIONS                           LCD
SSH
CC
NIST
5 Digit LCD
316 Stainless Steel Housing (Only w/WP housing)
Custom Calibration
NIST Traceable Calibration Certificate 
Service: Compatible gases, steam, liquids or vapors.
Wetted Materials: 316L SS.
Accuracy: ±0.075% FS (@ 20°C).
Rangeability: 100:1 turn down.
Stability: ±0.125% FSO/yr.
Temperature Limits: Process: -40 to 248°F (-40 to 120°C); Ambient (without LCD): -40 to 185°F (-40 to 85°C); Ambient (with LCD): -22 to 176°F (-30 to 80°C).
Pressure Limits: Max. pressure: Range: -14.5 to 2000 psi; Burst pressure: 10000 psi.
Thermal Effect: ±0.125% span/32°C.
Power Requirements: 11.9 to 45 VDC.
Output Signal: 4 to 20 mA/HART® Communication.
Response Time: 0.12 seconds.
Damping Time: 0.25-60 seconds.
Loop Resistance: Operation: 0 to 1500 Ohm; HART® Communication: 250 to 500 Ohm.
Electrical Connection: Two 1/2" female NPT conduit, screw terminal.
Process Connection: 1/4" female NPT.
Display: Optional 5 digit LCD.
Enclosure Rating: NEMA 4X (IP66) and explosion-proof for Class I, Div I, Groups A, B, C and D.
Weight: 8.6 lb (3.9 kg).
Agency Approvals: CE, FM, ATEX option available (consult factory).
  • Configurable using zero/span buttons means no calibrator required reducing time to install and running.
  • Range-ability and selectable engineering units, allows transmitter to fit many applications reducing the number of different transmitters to meet specifications.
  • High accuracy (±0.075%) provides exceptional measurement for insuring tightcontrol and minimizing costly out of specification conditions.
  • Automatic sensor temperature compensation improves performance of device for accurate measurement under different operating environments.
  • Fail-mode process function stores configuration settings in the event of shutdown or power-loss provides for faster restart to getting application back on-line.
  • A HART® Communication programmable device provides a reliable, long-term solution for plant operators who seek the benefits of intelligent devices with digital communication.