Series 211/213/214 Flanged Chamber Level Control

Flanged Chamber Level Control External Mount, Pressure to 450 psig (31 bar), Temperature to 500°F (260°C)

Series 211/213/214 Flanged Chamber Level Control

A removable stainless steel float enclosed in a flanged carbon steel chamber is featured in the durable, field proven 211 Series. External side mount series includes 1" NPT process connections as standard, or with socket weld hubs; or, 1" flanges as options. Pressure and temperature limits are 450 psi (31 bar) at 100°F (38°C), and 300 psi (21 bar) at 500°F (260°C). Minimum specific gravity for all models is 0.60. The models shown can be ordered with a variety of electrical arrangements including SPST, SPDT, or DPDT circuits in hermetically sealed snap action or mercury contacts. Switches can be ordered open on level rise or fall. Single pole double throw electrically independent circuits are available as well as low current or high DC current applications. A full range of enclosures are offered including general purpose NEMA 1; weatherproof NEMA 4X; (explosion-proof) and (explosion-proof/vapor-proof) Groups B, C, D, E, F, G, NEMA 7, 9.

Product Applications

  • Oil refineries
  • Chemical plants
  • Power generating stations
  • Pumping stations
  • Heat transfer systems
  • Sanitary/waste water facilities
  • Drip legs
  • hydraulic systems
  • boilers
More Information
Model Chart
EXAMPLE2112WT7810-10C160L12211-2-WT-7810-10-C1-60-L12 Level Control, flanged carbon steel chamber, weatherproof enclosure, (2) SPDT snap action switches, lower stage adjustable deadband, upper stage fixed deadband, operating pressure 450 psig @ 100°F, side/bottom 1" NPT process connections, minimum s.g. 0.60.
CONNECTION211      One Horizontal and One Vertical 1" NPT
213      One Vertical and One Horizontal Flanged Connection
214      Two Vertical Flanged Connections
DEADBAND 1     Single Stage Operation, with Adjustable Deadband
 2     Two Stage Operation, Lower Stage has Adjustable Deadband, Upper Stage has Fixed Deadband
 3     Two Stage Operation, Lower Stage has Fixed Deadband, Upper Stage has Adjustable Deadband
 4     Two Stage Operation, Both Stages have Fixed Deadband with Adjustable Spread Between Stages
ENCLOSURE   G    General Purpose, NEMA 1
  WT    Weatherproof, NEMA 3R, 4, 4X
  E    Explosion-proof, NEMA 7, 9, Class I Groups B, C, D, Class II Groups E, F, G
  EV    Explosion-proof/Vapor-proof, NEMA 7, 9, Class I Groups B, C, D, Class II Groups E, F, G
CIRCUITS
(for electrical circuits
see charts A & B below)
   48XX   Single Stage Mercury Switch, see chart A
   48XX-XX   Two Stage, Mercury Switch, see chart A
   78XX   Single Stage, Snap Switch, see chart B
   78XX-XX   Two Stage, Snap Switch, see chart B
   78XXHM   Hermetically Sealed Snap Switch, see chart B
   98XX   Single Stage, High Capacity DC Snap Switch, use heat fins (HF) if process temperature exceeds 350°F (177°C), do not exceed 450°F (232°C), see chart B
   98XX-XX   Two Stage, High Capacity DC Snap Switch, use heat fins (HF) if process temperature exceeds 350°F (177°C), do not exceed 450°F (232°C), see chart B
CHAMBER MATERIAL    C1  Carbon Steel Body
    C216  316SS Body
    HFC1  Heat Fins & Carbon Steel Body
    HFC216  Heat Fins & 316SS Body (211 only)
MINIMUM
SPECIFIC
GRAVITY
     60 0.60 Specific Gravity (211 only)
     160 0.60 Specific Gravity & 150# Flange (213, 214 only)
     360 0.60 Specific Gravity & 300# Flange (213, 214 only)
     660 0.60 Specific Gravity & 600# Flange (213, 214 only)
OPTIONS      H2H2 Socket Weld Hub  (211, steel housing only)
      RManual Reset, Single Stage
      R1Manual Reset, Lower Stage 2-Stage Control
      R2Manual Reset, Upper Stage 2-Stage Control
      R3Manual Reset, Both Stages 2-Stage Control
      STWSS Tag Wired
      01Breather Only (E-Housing only)
      02Drain Only (E-Housing only)
      12Breather & Drain (E-Housing only)
      23720Fungus Proofing


CHARTS A & B - ELECTRICAL CIRCUITS AND RATINGS

SWITCH TYPE
SWITCH ACTION
ELECTRICAL RATINGS IN AMPS
ORDERING CODE
AC
DC
SINGLE STAGE
TWO STAGE
120V
240V
440V
30V
125V
250V
LOWER
UPPER
CHART A
Mercury Contacts
SP-ST open on level FALL
10
5
3†
 
10
5
-4821
-4821
-21
SP-ST open on level RISE
10
5
3†
 
10
5
-4820
-4820
-20
SP-DT one switch
4
2
1†
 
4
2
-4810
-4810
-10
SP-DT two switches E.I.*
10
5
3†
 
10
5
-4815
-4815
-15
DP-ST two switches E.I.* open on level FALL
10
5
3†
 
10
5
-4813
-4813
-13
DP-ST two switches E.I.* open on level RISE
10
5
3†
 
10
5
-4814
-4814
-14
DP-DT two SP-DT switches
4
2
1†
 
4
2
-4806
-4806
-06
CHART B
snap action contacts
SP-DT one switch
12
5
3†
 
0.5**
0.25**
-7810
-7810
-10
DP-DT two SP-DT switches
12
5
3†
 
0.5**
0.25**
-7806
-7806
-06
SP-DT one hermetically sealed switch
5
5
 
5**
 
 
-7810HM
-7810HM
-10HM
DP-DT two hermetically sealed SP-DT switches
5
5
 
5**
 
 
-7806HM
-7806HM
-06HM
DP-DT two SP-DT switches
10
3
 
 
10‡
3‡
-9806
-9806
-06
SP-DT one switch
10
3
 
 
10‡
3‡
-9810
-9810
-10
DP-DT Two SP-DT switches
2
2
 
 
0.4**
0.25**
-1006
-1006
-06
SP-DT one switch
2
2
 
 
0.4**
0.25**
-1010
-1010
-10

Minimum Specific Gravity:0.60
Switch Type:Snap or mercury switch. See charts A and B on Model Chart.
Electrical Rating:See charts A and B on Model Chart.
Wiring Connections:G, WT or E enclosure, terminal block. EV enclosure, 18" (460 mm) leads.
Process Connections:1" NPT standard (socket weld hubs or flanges optional). See Model Chart.
Enclosures:G, painted steel and aluminum. WT, painted steel, aluminum and neoprene. E, aluminum. EV, aluminum and neoprene.
Wetted Parts:C1 construction. Chamber: carbon steel; Trim: 303SS, 304SS, and 430SS (316SS and 430SS optional).
Weight:211: 34 lb (15 kg); 213: 44 lb (20 kg); 214: 51 lb (23 kg).