LC-100 PRECISION LOOP CALIBRATOR

The Martel Electronics LC-100 Precision Loop Calibrator provides significantly extended performance when compared to any competitive calibrator. With an accuracy of 0.015% of reading, with 0.001 mA resolution, the LC-100 has the highest accuracy in its class. Unique features, such as a “% Error” function, which eliminates manual error calculation and allows the display of the actual versus ideal error at any calibration point, put the LC-100 way beyond similar instruments. The Martel LC-100 can simulate, power, and measure two-wire transmitters. With automatic Step and Ramp functions, the LC-100 enables remote calibration of 4-20mA devices.
The Martel Electronics LC-100 Precision Loop Calibrator provides significantly extended performance when compared to any competitive calibrator. With an accuracy of 0.015% of reading, with 0.001 mA resolution, the LC-100 has the highest accuracy in its class. Unique features, such as a “% Error” function, which eliminates manual error calculation and allows the display of the actual versus ideal error at any calibration point, put the LC-100 way beyond similar instruments. The Martel LC-100 can simulate, power, and measure two-wire transmitters. With automatic Step and Ramp functions, the LC-100 enables remote calibration of 4-20mA devices.
More Information
Features
  • Very high accuracy – ±0.015% of reading
  • Very high resolution – 0.001mA/0.001V
  • % Error function – eliminates manual error calculation
  • Extended adjustment range – digital knob and user-selectable decade output allow both large and incremental (0.001 mA step) output changes
  • Reads 0 to 28.000 VDC
  • Built in 250 Ohm resistor facilitates calibration of HART devices
  • Remote calibrations through Automatic Step and Ramp functions
  • Loop power measurements capability
  • Simulates, powers, and measures two-wire transmitters
  • Five preset outputs (4, 8, 12, 16, 20 mA)
  • Fuseless input protection up to 250 VAC
  • Supplied in full rubber boot; optional carrying case available
  • Very high accuracy – ±0.015% of reading
  • Very high resolution – 0.001mA/0.001V
  • % Error function – eliminates manual error calculation
  • Extended adjustment range – digital knob and user-selectable decade output allow both large and incremental (0.001 mA step) output changes
  • Reads 0 to 28.000 VDC
  • Built in 250 Ohm resistor facilitates calibration of HART devices
  • Remote calibrations through Automatic Step and Ramp functions
  • Loop power measurements capability
  • Simulates, powers, and measures two-wire transmitters
  • Five preset outputs (4, 8, 12, 16, 20 mA)
  • Fuseless input protection up to 250 VAC
  • Supplied in full rubber boot; optional carrying case available