Industrial series

Industrial series

Design
EN 837-3

Nominal size in mm
63, 100, 160

Accuracy class
1.6

Scale ranges
NS 63: 0 ... 25 mbar to 0 ... 600 mbar
NS 100: 0 ... 10 mbar to 0 ... 600 mbar
NS 160: 0 ... 6 mbar to 0 ... 600 mbar
or all other equivalent vacuum or combined pressure and vacuum ranges

Pressure limitation
Steady: Full scale value
Fluctuating: 0.9 x full scale value

Permissible temperature
Ambient: 
-20 … +60 °C
Medium: 
+100 °C maximum
+ 80 °C maximum (with NS 100 and 160 back mount)

Temperature effect
When the temperature of the measuring system deviates from the reference temperature (+20 °C):
Max. ±0.6 %/10 K of full scale value

Ingress protection
IP 54 per EN 60529 / lEC 529

More Information
Applications Robust design and ingress protection IP 54 For gaseous, dry and non-aggressive media Medical, vacuum, environmental, laboratory technology, for contents measurement and filter monitoring
Model No 612.2
Special Features
  • Zero adjustment through window
  • Stainless steel case
  • Special location of connection on request
  • Low scale ranges from 0 ... 6 mbar