Differential pressure (Price & availability on application)

Design Per EN 837-3 and ventilation and air-conditioning (VAC) regulations Nominal size in mm 110 Accuracy class ±3 % (±5 % with scale range ≤ 0 ... 125 Pa) Scale ranges 0 … 50 Pa to 0 … 12,500 Pa -25 … +25 Pa to -1,500 … +1,500 Pa further plus/minus ranges on request Pressure limitation Steady: Full scale value Fluctuating: Full scale value Overpressure safety 20 kPa Max. working pressure (static pressure) 20 kPa Permissible temperature Ambient: -30 ... +80 °C Medium: -16 … +50 °C Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.5 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
Design Per EN 837-3 and ventilation and air-conditioning (VAC) regulations Nominal size in mm 110 Accuracy class ±3 % (±5 % with scale range ≤ 0 ... 125 Pa) Scale ranges 0 … 50 Pa to 0 … 12,500 Pa -25 … +25 Pa to -1,500 … +1,500 Pa further plus/minus ranges on request Pressure limitation Steady: Full scale value Fluctuating: Full scale value Overpressure safety 20 kPa Max. working pressure (static pressure) 20 kPa Permissible temperature Ambient: -30 ... +80 °C Medium: -16 … +50 °C Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.5 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
More Information
Applications For dry, clean, non-aggressive gases, usually air | Fan and blower monitoring | Differential pressure monitoring in filters | Overpressure monitoring in cleanrooms | For very low pressures
Description Design Per EN 837-3 and ventilation and air-conditioning (VAC) regulations Nominal size in mm 110 Accuracy class ±3 % (±5 % with scale range ≤ 0 ... 125 Pa) Scale ranges 0 … 50 Pa to 0 … 12,500 Pa -25 … +25 Pa to -1,500 … +1,500 Pa further plus/minus ranges on request Pressure limitation Steady: Full scale value Fluctuating: Full scale value Overpressure safety 20 kPa Max. working pressure (static pressure) 20 kPa Permissible temperature Ambient: -30 ... +80 °C Medium: -16 … +50 °C Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.5 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
Model No A2G-10
Special Features Zero adjustment in front Simple mounting and dismounting Two-part construction (measuring element and case) Optional version with additional electrical output signal (model A2G-15)