Bourdon tube pressure gaugeUHP, stainless steel, safety pattern (Price & availability on application)

Design
EN 837-1

Nominal size in mm
63

Accuracy class
1.6

Scale ranges
0 ... 1 to 0 ... 400 bar (0 ... 15 to 0 ... 6000 psi)
or all other equivalent vacuum or combined pressure and vacuum ranges

Pressure limitation
Steady: 3/4 x full scale value
Fluctuating: 2/3 x full scale value
Short time: full scale value

Operating temperature
Ambient: -40 ... +60 °C
Medium: +100 °C maximum

Temperature effect
When the temperature of the measuring system deviates from the reference temperature (+20 °C):
max. ±0.4 %/10 K of full scale value

Ingress protection
IP 54 per EN 60529 / IEC 529
Product Description

Details

Design EN 837-1 Nominal size in mm 63 Accuracy class 1.6 Scale ranges 0 ... 1 to 0 ... 400 bar (0 ... 15 to 0 ... 6000 psi) or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: full scale value Operating temperature Ambient: -40 ... +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / IEC 529
Additional Information

Additional Information

Applications Increased safety requirements | For gaseous and liquid, also corrosive media, also in a corrosive environment, for demanding high purity applications | For all UHP (Ultra High Purity) applications | Semiconductor and flat panel industry | Gas distribution systems, medical gases, hook-up application
Description Design EN 837-1 Nominal size in mm 63 Accuracy class 1.6 Scale ranges 0 ... 1 to 0 ... 400 bar (0 ... 15 to 0 ... 6000 psi) or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: full scale value Operating temperature Ambient: -40 ... +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / IEC 529
Model No 232.35
Special Features Safety pressure gauge with solid baffle wall designed in compliance with operational safety requirements of EN 837-1 | VCR® compatible face seal fittings | Helium leak tested | Electropolished caset