Fluke 772 mA Process Clamp Meter

Milliamp process clamp meters can measure mA signals without breaking the loop. The Fluke 772 Milliamp Clamp Meter expand upon the capabilities of the popular 771 mA Clamp Meter, adding loop power and mA sourcing to the troubleshooting and process calibration capabilities in all Fluke mA clamp meters.

Measure 4-20 mA signals without breaking the loop with this new, compact clamp meter for PLC and control systems analog I/O. The detachable clamp with extension cable allows you to take measurements in tight locations, and the built-in spot light illuminates hard to see wires in dark enclosures.

Milliamp process clamp meters can measure mA signals without breaking the loop. The Fluke 772 Milliamp Clamp Meter expand upon the capabilities of the popular 771 mA Clamp Meter, adding loop power and mA sourcing to the troubleshooting and process calibration capabilities in all Fluke mA clamp meters.

Measure 4-20 mA signals without breaking the loop with this new, compact clamp meter for PLC and control systems analog I/O. The detachable clamp with extension cable allows you to take measurements in tight locations, and the built-in spot light illuminates hard to see wires in dark enclosures.

More Information
Features
  • Best in class 0.2 % accuracy.
  • 0.01 mA resolution and sensitivity.
  • Measure 4 to 20 mA signals without ”breaking the loop” .
  • Measure mA signals for PLC and control system analog I/O.
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span.
  • Measurement Spotlight illuminates hard to see wires in dark enclosures.
  • Detachable clamp with extension cable for measurements in tight locations.
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range.
  • Automatically change the 4 to 20 mA output for remote testing.
  • Power saving features, auto-off, backlight timeout extend battery life.
  • Hold function captures and displays changing measurements.
  • Measure 4 to 20 mA signals with in-circuit measurement.
  • Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters.
  • Source 4 to 20 mA signals for testing control system I/O or I/Ps.
  • mA output linear ramp or 25% step output.
  • Automatically change the 4 to 20 mA output for remote testing.
Model Fluke Model 772 mA Process Clamp Meter
Specifications

Are you spending time:

  • Taking mA measurements by removing a wire and breaking the loop.

  • Calling the control room to isolate a loop.

  • Testing analog input/output on a console.

  • Troubleshooting devices with mA inputs and outputs.

  • Repairing intermittent erratic 4 to 20mA loops.

  • Coming back to the shop to get extra tools.

If you need more time in your busy day take a look at the Fluke 772 mA Clamp Meters. It's designed to save you time and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4 to 20mA loops without breaking the loop or bringing down the system.

 

Here are some specific ways the Fluke 772 Clamp Meter will help you

Milliamp Clamp Features Application How it saves time 
and money
Measures mA signals for PLC and
control system analog I/O without
breaking the loop
Measures low level DC current Correlate process indication
with real physical value
Measure output signals from
transmitters without breaking the loop
Maintain and troubleshoot process
and automation equipment without
breaking the loop
No disruption to the process
Detachable clamp with extension
cable
Measurements in tight locations Enables measurements in
difficult situations
Measurement Spotlight Illuminates hard to see wires in dark
enclosures
Measurement process is 
easier and quicker
Measure up to 99.9mA range 
non-contact
Wide range of measurements Measures 10 to 50mA signals
in older control systems
Automatic power off After 15 minutes and 2 minutes
automatic off for backlight and spotlight
Saves battery life
 

What's the difference between the 77X models?

Models

Fluke 771 Fluke 772 Fluke 773

Measurement

Non-contact mA loop
measurement
Integrated mA loop
troubleshooting
Advanced process
troubleshooting

mA measure, jaw

mA measure, in circuit

 

Loop power

 

mA source

 

DCV measurement

   

DCV source

   

mA scaled output

   

mA in/out

   

Are you spending time:

  • Taking mA measurements by removing a wire and breaking the loop.

  • Calling the control room to isolate a loop.

  • Testing analog input/output on a console.

  • Troubleshooting devices with mA inputs and outputs.

  • Repairing intermittent erratic 4 to 20mA loops.

  • Coming back to the shop to get extra tools.

If you need more time in your busy day take a look at the Fluke 772 mA Clamp Meters. It's designed to save you time and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4 to 20mA loops without breaking the loop or bringing down the system.

 

Here are some specific ways the Fluke 772 Clamp Meter will help you

Milliamp Clamp Features Application How it saves time 
and money
Measures mA signals for PLC and
control system analog I/O without
breaking the loop
Measures low level DC current Correlate process indication
with real physical value
Measure output signals from
transmitters without breaking the loop
Maintain and troubleshoot process
and automation equipment without
breaking the loop
No disruption to the process
Detachable clamp with extension
cable
Measurements in tight locations Enables measurements in
difficult situations
Measurement Spotlight Illuminates hard to see wires in dark
enclosures
Measurement process is 
easier and quicker
Measure up to 99.9mA range 
non-contact
Wide range of measurements Measures 10 to 50mA signals
in older control systems
Automatic power off After 15 minutes and 2 minutes
automatic off for backlight and spotlight
Saves battery life
 

What's the difference between the 77X models?

Models

Fluke 771 Fluke 772 Fluke 773

Measurement

Non-contact mA loop
measurement
Integrated mA loop
troubleshooting
Advanced process
troubleshooting

mA measure, jaw

mA measure, in circuit

 

Loop power

 

mA source

 

DCV measurement

   

DCV source

   

mA scaled output

   

mA in/out

   
  • Best in class 0.2 % accuracy.
  • 0.01 mA resolution and sensitivity.
  • Measure 4 to 20 mA signals without ”breaking the loop” .
  • Measure mA signals for PLC and control system analog I/O.
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span.
  • Measurement Spotlight illuminates hard to see wires in dark enclosures.
  • Detachable clamp with extension cable for measurements in tight locations.
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range.
  • Automatically change the 4 to 20 mA output for remote testing.
  • Power saving features, auto-off, backlight timeout extend battery life.
  • Hold function captures and displays changing measurements.
  • Measure 4 to 20 mA signals with in-circuit measurement.
  • Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters.
  • Source 4 to 20 mA signals for testing control system I/O or I/Ps.
  • mA output linear ramp or 25% step output.
  • Automatically change the 4 to 20 mA output for remote testing.