Series LCI308 & LCI408 Panel Meter Indicator

Panel Meter Indicator 1/8 DIN, High Accuracy, Peak & Valley Display

1/8 DIN, High Accuracy, Peak & Valley Display

The Series LCI308 and LCI408 Panel Meter Indicators offer flexibility and value in a standard 1/8 DIN package. This family of indicators offers input availability for virtually all types of process measurement.

The LCI308 offers a 4-3/4 digit display scalable to ±32,000 counts. This flexible indicator is available for Process Inputs (0-10 VDC, 4-20 mA, etc.), Temperature Inputs (Thermocouple Types J, K, T, and DIN RTD), Timer/Counter type, and Load Cell (strain gage) Inputs.

The LCI408 has a universal input that accepts the Process, Temperature, and Load Cell inputs of the LCI308, plus a Potentiometer input. The full 5-digit display can be scaled between ±99999 counts. The dual display allows simultaneous display of the measured value plus other values such as peak or valley.

Options include relay and transistor set point outputs, BCD Parallel output, RS-232/RS-485 computer communications, and 4 to 20 mA analog retransmission.

Inputs: Process, Temperature (T/C & RTD), frequency/counter, load cell (dependent on model number).
Input Impedance: Process: Voltage, 1 MΩ; current, 12.1Ω. Load Cell: 100 MΩ for 300 mV, 1 MW for 30 mV.
Display: 5-digit, 7 segment, 14 mm red with a fixed decimal point. 14 LEDs (programming & control).
Accuracy: LCI308: ±0.1% of reading (except temperature inputs). Thermocouples: ±0.4% of reading for types J, K, T, & E / ±.05% of reading for types R & S. RTD: ±0.2% of reading. LCI408: ±0.1% of reading.
Power Requirements: 115/230 VAC 50/60 Hz ±10%.
Power Consumption: 3W max.
Weight: 8 oz (250 g).
Front Panel Rating: IP65 (Type 4X).
Agency Approvals: CE.