Series 477AV Handheld Digital Manometer

Handheld Digital Manometer Measures Pressure, Flow and Velocity; ±0.5% Accuracy

Measures Pressure, Flow and Velocity; ±0.5% Accuracy

The SERIES 477AV Handheld Digital Manometer is now available with pressure, flow, and velocity measurements along with a number of other convenient features. The built-in air velocity and flow calculations provide accuracy and conserve time and error associated with manual calculations. Also featured on this unit are adjustable zero and span values for calibrating in the field, as well as a damping feature to compensate for the fluctuating of readings.

Product Applications

  • Air flow monitoring, when used with a Dwyer® Pitot tube
  • Duct static pressure
More Information
Model Chart
EXAMPLE 477AV 2 NIST 477AV-2-NIST, 477AV Differential Pressure Manometer w/ AV and Flow, 40” w.c./10 kPa Range, NIST Calibrated
RANGE   000
00
0
1
2
3
4
5
6
7
8
  1” w.c. / 0.249 kPa
4” w.c. / 0.995 kPa
10” w.c. / 2.49 kPa
20” w.c. / 5 kPa
40” w.c. / 10 kPa
200” w.c. / 50 kPa
10 psi / 70 kPa
20 psi / 140 kPa
30 psi / 200 kPa
100 psi / 700 kPa
150 psi / 1000 kPa
OPTIONS     COC
FC
NIST
Certificate of Calibration
Factory Calibration Certificate
NIST Traceable Calibration Certificate
Service: Air and compatible gases.
Wetted Materials: Consult factory.
Accuracy: ±0.5% FS, 60 to 78°F (15.6 to 25.6°C); ±1.5% FS from 32 to 60°F and 78 to 104°F (0 to 15.6°C and 25.6 to 40.0°C).
Pressure Hysteresis: ±0.1% of full scale.
Pressure Limits: See chart on catalog page.
Temperature Limits: 0 to 140°F (-17.8 to 60°C).
Compensated Temperature Limits: 32 to 104°F (0 to 40°C).
Storage Temperature Limits: -4 to 176°F (-20 to 80°C).
Display: 0.42" (10.6 mm) 4 digit LCD.
Resolution: See chart on catalog page.
Units of Pressure: in w.c., ft. w.c., in Hg, psi, oz/in², mm w.c., cm w.c., mm Hg, mbar, Pa, kPa, hPa.
Units of Velocity: fpm, fps, mph, m/h, m/s, k/h, knot.
Units of Flow: cfm, m3/h, m3/s.
Power Requirements: 9 V Alkaline battery, installed non-functional, user replaceable.
Weight: 10.2 oz (289 g).
Process Connections: Two barbed connections for use with 1/8" (3.18 mm) or 3/16" (4.76 mm) ID tubing. Two compression fittings for use with 1/8" (3.18 mm) ID x 1/4" (6.35 mm) OD tubing for 477AV-7 and 477AV-8 only.
Agency Approvals: CE.
  • Calculates and displays air velocity and volumetric air flow
  • Rugged aluminum case protects instrument from damage during transport/use
  • 9 selectable English and metric engineering units
  • Large, easy to read display with backlight for use in dark areas
  • Stores up to 40 readings with minimum, maximum and average statistics