Model ULSL Ultrasonic Level Sensor

Ultrasonic Level Sensor 18' (5.5 m) Measuring Range, Non-Contact Transmitter, 4 SPST Programmable Relays

18' (5.5 m) Measuring Range, Non-Contact Transmitter, 4 SPST Programmable Relays

The Model ULSL Ultrasonic Level Sensor provides non-contact, continuous ultrasonic level measurement of fluids for short range applications. Ultrasonic technology paired with automatic temperature compensation provides accurate and reliable measurements in almost all conditions. The Model ULSL has failsafe logic that is easily configured to custom applications via free software removing the need for target calibration. Using the free software, the Model ULSL can be programmed to transmit an output signal as well as set the four relays for control applications. This rugged design comes with a NEMA 6P submersible enclosure rating to ensure a long lasting unit.

Product Applications

  • Water and wastewater
  • Pulp and paper processing
  • Sump and process tanks
  • Chemical processing
  • Food and beverage
Service: Compatible fluids.
Wetted Materials: Sensor: PVDF; O-ring: FKM.
Ranges: 18' (5.5 m).
Accuracy: ±0.2% of range.
Resolution: 0.079" (2 mm).
Blind Zone: 8" (20 cm).
Beam Width: 3" (7.62 cm).
Temperature Limits:: Process: 20 to 140°F (-7 to 60°C); Ambient: -31 to 140°F (-35 to 60°C).
Temperature Compensation: Automatic.
Pressure Limits: 30 psi (2 bar).
Power Requirement: 12 to 28 VDC.
Output Signal:: 4 to 20 mA, 2-wire. Invert: 4 to 20 mA or 20 to 4 mA; Fail-safe: 4 mA, 20 mA, 21 mA, 22 mA, or hold last.
Loop Resistance: 400 Ω max.
Electrical Connections: 4' (1.2 m) 9 conductor shielded cable.
Contact Type: 4 SPST relays.
Contact Rating: 1 A max @ 28 VDC max.
Deadband: Selectable (no hysteresis, 1/4", 1/2", 1", 1/2 cm, 1 cm, 2 cm, 5 cm or not available).
Process Connection:: Process Connection: 2" NPT, 2" BSPP (optional).
Enclosure Rating: NEMA 6P (IP68).
Enclosure Material: Polycarbonate; Gland: TPE.
Mounting Orientation: Vertical.
Memory: Non-volatile.
Failsafe: Contact: Power loss: Hold last contact; Power on: Open, close, or last contact.
Programming: Free PC software download (USB adapter required).
Weight: 3 lb (1.36 kg).
Agency Approvals: CE, RoHS.
  • Has a 18´ (5.5 m) measuring range with a ±0.2% of range accuracy
  • Via free software, units can be programmed to transmit an output signal and operate four relays for control applications
  • Provides reliable, accurate, and non-contact level measurement of compatible liquids
  • Non-contact technology offers no moving parts to wear, jam, corrode, or get coated like contact technologies
  • Mapping software makes effective measuring surface only a 3" (76.2 mm) diameter column with no concerns of ladders, pipes, or other tank intrusions in the remaining sound cone
  • Ultrasonic technology paired with automatic temperature compensation provides accurate and reliable measurements in almost all conditions
  • Fail-safe logic is easily configured to custom applications via free software removing the need for target calibration
  • Full NEMA 6P submersible enclosure rating to ensure excellent product durability