Series F7-MQ Quick-Ship Multi-Station Level Switch

Quick-Ship Multi-Station Level Switch Fast Delivery, Customized, Up to Four Actuation Levels

Fast Delivery, Customized, Up to Four Actuation Levels

The SERIES F7-MQ Quick-Ship Multi-Station Level Switches provides a customized level switch to meet application requirements. Switches can be configured with up to four different control points and stem lengths up to 72" (1.82 m). Stems and floats are available in 316 SS or brass, SPST or SPDT switches, and choice of mountings.

Product Applications

  • Water level monitoring
  • Oil level control
  • Tank level control
  • Diesel level monitoring
More Information
Model Chart
EXAMPLE F7-MQ B 2 4 F1 1 03.25 06.50 09.75 15.00 24.00 20 Series F7-MQB2-4F11-03.25-06.50-09.75-15.00-24.00-20 Quick-Ship Multi-Station Level Switch, brass with beryllium copper stops, 1/2" NPT, 4 switch points, Buna-N float, min. s.g. 0.75, max. pressure 150 psi, SPST, .17A @ 120VAC, L4 set point distance 3.25", L3 set point distance 6.5", L2 set point distance 9.75", L1 set point distance 15", 24" overall length, with 20' lead wire.
SERIES F7-MQ                       Quick-Ship Multi-Station Level Switch
STEM & CONN.
MATERIAL
  B
S
                    Brass with Beryllium Copper Stops
316SS with SS Armco PH-15-7MO Stops
CONNECTION
TYPE
    1
2
3
                  1/2" NPT (float F2 and F3 only)
1-1/4" NPT (float F1 only)
2" NPT (float F2 and F3 only)
NUMBER OF
SWITCH
POINTS
      1
2
3
4
                1 Switch Point
2 Switch Points
3 Switch Points
4 Switch Points
FLOAT TYPE         F1
F2
F3
              Buna-N, Min. S.G. 0.75, Max. Pressure 150 psi (10.3 bar)
Buna-N, Min. S.G. 0.55, Max. Pressure 150 psi (10.3 bar)
316SS, Min. S.G. 0.75, Max. Pressure 750 psi (51.7 bar)
SWITCH TYPE           1
2
3
            SPST NO, .17 A @ 120 VAC
SPST NC, .8 A @ 120 VAC
SPDT, .17 A @ 120 VAC
NO switch is standard. For NC place and "*" after the corresponding set point distance in the model number.
SET POINT
DISTANCE
(L4)
            00.00           In inches referenced from bottom of connection. Example: 03.25 would be 3.25" from the bottom of the process connection.
SET POINT
DISTANCE
(L3)
              00.00         In inches referenced from bottom of connection. Example: 06.50 would be 6.50" from the bottom of the process connection.
SET POINT
DISTANCE
(L2)
                00.00       In inches referenced from bottom of connection. Example: 09.75 would be 9.75" from the bottom of the process connection.
SET POINT
DISTANCE
(L1)
                  00.00     In inches referenced from bottom of connection. Example: 15.00 would be 15" from the bottom of the process connection.
OVERALL
LENGTH
(LO)
                    00.00   Maximum overall length of 72" (1.82 m). Minimum length is L1 + D.
OPTIONS                       J
00
Junction Box for Wire Leads, NEMA 4
Lead Wire Length (in feet)

Service:Compatible liquids.
Temperature Limits:F1 and F2 with water: 0 to 180°F (-18 to 82°C); oil: -40 to 230°F (-40 to 110°C); F3: -40 to 300°F (-40 to 149°C).
Electrical Connections:24" (61 cm) free leads; #22 AWG TFE and #18 AWG polymeric.
Mounting Orientation:Vertical ±30°.

  • Customized level indication quickly and affordably
  • Rugged construction with multiple options yielding exceptional versatility
  • Capable of supporting larger, more buoyant floats
  • Durable construction asserts long reliability in contaminated or turbulent media