Fluke 376 AC/DC True-Rms Clamp Meter with iFlex

The Fluke 376 Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With True-rms voltage and current measurements the Fluke 376 can read up to 1000 Amps in both AC and DC modes.

Additionally, the Fluke 376 includes the new iFlex™ flexible current probe, which expands the measurement range to 2500 Amps AC while providing increased display flexibility, ability to measure around awkward sized conductors and improved wire access.

The Fluke 376 Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With True-rms voltage and current measurements the Fluke 376 can read up to 1000 Amps in both AC and DC modes.

Additionally, the Fluke 376 includes the new iFlex™ flexible current probe, which expands the measurement range to 2500 Amps AC while providing increased display flexibility, ability to measure around awkward sized conductors and improved wire access.

More Information
Features
  • True Rms AC Voltage and Current for accurate measurements on non-linear signals.
  • iFlex™ flexible current probe expands the current measurement range to 2500A AC.
  • DC mV measurements to 500mV.
  • AC/DC Voltage measurements to 1000V.
  • Frequency measurement to 500Hz
  • Min/Max/Average and Inrush recording to capture variations automatically.
  • Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments while providing stable readings.
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.
  • Ergonomic design fits in your hand and can be used while wearing protective equipment.
  • State of the art signal processing allows for use in noisy electrical environments while providing stable readings.
  • Large easy to read backlit display automatically sets the correct measurement range so you do not need to change switch positions while taking a measurement.
  • IEC/EN 61010-1-2001, CAT III 600V.
  • 3-year warranty.
Model Fluke Model 376 AC/DC True-Rms Clamp Meter with iFlex
Specifications

Electrical Specifications

Measurement

Range

Accuracy

AC Voltage (True-Rms)

0 to 1000.0V

1.5% of reading + 5 digits

AC Current (True-Rms

0 to 999.9A

2.0% of reading + 5 digits

0 to 2500A

using iFlex™ Flexible Current Probe

DC Voltage

0 to 1000V

1.0% of reading + 5 digits

0 to 500mV

 

DC Current

0 to 999.9A

1.0% of reading + 5 digits

Resistance

0 to 60KΩ

1.0% of reading + 5 digits

Frequency

to 500Hz

Continuity

≤ 30Ω

Inrush

100ms

Min / Max / Avg

Yes

Vibration

Random 2g, 5Hz to 500Hz

Shock

One meter drop test (except the jaw)

Temperature Coefficient

0.01% / °C (< 18° or > 28°)

 

Environmental Specifications

Operating Temperature

-10°C to 50°C

Storage Temperature

-40ºC to +60ºC

Operating Humidity

< 90% at 10°C to 30°C, < 75% at 30°C to 40°C

Operating Altitude

3000 meters

 

Safety Specifications

Safety Rating

IEC 1010-1-2001, 600V CAT III, CAT IV 300V

 

General Specifications

Jaw Opening

34mm maximum (750 MCM)
18-inch iFlex™ Probe

Power Supply

Two 1.5V  type 'AA' Alkaline Batteries (IEC 1010-2-031)

Dimensions

248mm (L) x 85mm (W) x 45mm (D)

Weight

375g

Warranty

3-years for electronics, 1-year for cable and clamp assembly

 

Ordering Information

Model Name

Description

Fluke 376

AC/DC True-Rms Clamp Meter
Includes: 
Two type 'AA' Alkaline batteries, Coated Instruction Card, TL75 Test Leads, Safety Information Sheet, and Soft Carrying Case.

Electrical Specifications

Measurement

Range

Accuracy

AC Voltage (True-Rms)

0 to 1000.0V

1.5% of reading + 5 digits

AC Current (True-Rms

0 to 999.9A

2.0% of reading + 5 digits

0 to 2500A

using iFlex™ Flexible Current Probe

DC Voltage

0 to 1000V

1.0% of reading + 5 digits

0 to 500mV

 

DC Current

0 to 999.9A

1.0% of reading + 5 digits

Resistance

0 to 60KΩ

1.0% of reading + 5 digits

Frequency

to 500Hz

Continuity

≤ 30Ω

Inrush

100ms

Min / Max / Avg

Yes

Vibration

Random 2g, 5Hz to 500Hz

Shock

One meter drop test (except the jaw)

Temperature Coefficient

0.01% / °C (< 18° or > 28°)

 

Environmental Specifications

Operating Temperature

-10°C to 50°C

Storage Temperature

-40ºC to +60ºC

Operating Humidity

< 90% at 10°C to 30°C, < 75% at 30°C to 40°C

Operating Altitude

3000 meters

 

Safety Specifications

Safety Rating

IEC 1010-1-2001, 600V CAT III, CAT IV 300V

 

General Specifications

Jaw Opening

34mm maximum (750 MCM)
18-inch iFlex™ Probe

Power Supply

Two 1.5V  type 'AA' Alkaline Batteries (IEC 1010-2-031)

Dimensions

248mm (L) x 85mm (W) x 45mm (D)

Weight

375g

Warranty

3-years for electronics, 1-year for cable and clamp assembly

 

Ordering Information

Model Name

Description

Fluke 376

AC/DC True-Rms Clamp Meter
Includes: 
Two type 'AA' Alkaline batteries, Coated Instruction Card, TL75 Test Leads, Safety Information Sheet, and Soft Carrying Case.

  • True Rms AC Voltage and Current for accurate measurements on non-linear signals.
  • iFlex™ flexible current probe expands the current measurement range to 2500A AC.
  • DC mV measurements to 500mV.
  • AC/DC Voltage measurements to 1000V.
  • Frequency measurement to 500Hz
  • Min/Max/Average and Inrush recording to capture variations automatically.
  • Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments while providing stable readings.
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.
  • Ergonomic design fits in your hand and can be used while wearing protective equipment.
  • State of the art signal processing allows for use in noisy electrical environments while providing stable readings.
  • Large easy to read backlit display automatically sets the correct measurement range so you do not need to change switch positions while taking a measurement.
  • IEC/EN 61010-1-2001, CAT III 600V.
  • 3-year warranty.