Fluke 345 Power Quality Clamp Meter

This clamp on meter is a combination power analyzer, power quality logger, and clamp meter, and is ideal for monitoring electronic loads.

With the bright color power meter display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 power analyzer is ideal for troubleshooting power quality on switching loads. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit with the power meter. The internal memory of the power analyzer enables long-term power quality logging for analysis of trends or intermittent problems.

This clamp on meter is a combination power analyzer, power quality logger, and clamp meter, and is ideal for monitoring electronic loads.

With the bright color power meter display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 power analyzer is ideal for troubleshooting power quality on switching loads. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit with the power meter. The internal memory of the power analyzer enables long-term power quality logging for analysis of trends or intermittent problems.

More Information
Features
  • AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit.
  • Highest safety rating: 600 V CAT IV power analyzer is rated for use at the service entrance.
  • Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter.
  • Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics.
  • Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems.
  • Troubleshoot harmonics: Analyze and log harmonics digitally or graphically.
  • Inrush current: Capture and analyze nuisance tripping, from 3 seconds to 300 seconds.
  • Easy to use: Easily confirm power meter setup with large backlit color display of waveforms and trends.
  • 3-Phase power: Built in capability for balanced loads.
  • View graphs and generate reports: Use power analyzer with included Power Log software.                

 

Model Fluke Model 345 Power Quality Clamp Meter
Specifications

Operating Temperature

0°C to 50°C

Temperature Coefficient of Current

≤ ±0.15% of reading per °C

Temperature Coefficient of Voltage

≤ ±0.15% of reading per °C

Maximum Relative Humidity

3000 meters

Maximum Operating Altitude

2000 meters

 

Safety Specifications

Safety

IEC 61010-1 600V CAT IV, double or reinforced insulation, pollution degree 2

Protection

IP40; EN60529

Maximum Safe Working Voltages

Current measurement: 600V AC rms or DC between uninsulated conductor and ground

Voltage measurement: 600V AC rms or DC between either input terminal and ground, or 825V between energized phase voltages (delta power configuration)

EMC Emission

IEC / EN 61326-1:1997 Class B

EMC Immunity

IEC / EN 61326-1:1997

 

General Specifications

Display

Color transmissive LCD 320 x 240 pixels (70mm diagonal) with Two level backlight

Jaw Size

Opening: 60mm

Capacity: 58mm diameter

Power Supply

Six 1.5-volt type 'AA' Alkaline MN 1500 or IEC LR6 batteries

Battery Life

greater than 10 hours (backlight on full)

greater than 12 hours (backlight reduced)

Battery Eliminator (BE345)

110V to 230V AC 50/60Hz; Output 15V DC, 300mA

Dimensions

300mm (L) x 98mm (W) x 52mm (D)

Weight

820g (including batteries)

 

Ordering Information

Model Name

Description

Fluke 345

Power Quality Clamp Meter
Includes:
Six type 'AA' Alkaline batteries, Power Log software, Test Leads, Alligator Clips, Test Probes, USB cable International AC Adapter/Battery Eliminator, User's manual, and Soft Carrying Case.

Operating Temperature

0°C to 50°C

Temperature Coefficient of Current

≤ ±0.15% of reading per °C

Temperature Coefficient of Voltage

≤ ±0.15% of reading per °C

Maximum Relative Humidity

3000 meters

Maximum Operating Altitude

2000 meters

 

Safety Specifications

Safety

IEC 61010-1 600V CAT IV, double or reinforced insulation, pollution degree 2

Protection

IP40; EN60529

Maximum Safe Working Voltages

Current measurement: 600V AC rms or DC between uninsulated conductor and ground

Voltage measurement: 600V AC rms or DC between either input terminal and ground, or 825V between energized phase voltages (delta power configuration)

EMC Emission

IEC / EN 61326-1:1997 Class B

EMC Immunity

IEC / EN 61326-1:1997

 

General Specifications

Display

Color transmissive LCD 320 x 240 pixels (70mm diagonal) with Two level backlight

Jaw Size

Opening: 60mm

Capacity: 58mm diameter

Power Supply

Six 1.5-volt type 'AA' Alkaline MN 1500 or IEC LR6 batteries

Battery Life

greater than 10 hours (backlight on full)

greater than 12 hours (backlight reduced)

Battery Eliminator (BE345)

110V to 230V AC 50/60Hz; Output 15V DC, 300mA

Dimensions

300mm (L) x 98mm (W) x 52mm (D)

Weight

820g (including batteries)

 

Ordering Information

Model Name

Description

Fluke 345

Power Quality Clamp Meter
Includes:
Six type 'AA' Alkaline batteries, Power Log software, Test Leads, Alligator Clips, Test Probes, USB cable International AC Adapter/Battery Eliminator, User's manual, and Soft Carrying Case.

  • AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit.
  • Highest safety rating: 600 V CAT IV power analyzer is rated for use at the service entrance.
  • Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter.
  • Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics.
  • Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems.
  • Troubleshoot harmonics: Analyze and log harmonics digitally or graphically.
  • Inrush current: Capture and analyze nuisance tripping, from 3 seconds to 300 seconds.
  • Easy to use: Easily confirm power meter setup with large backlit color display of waveforms and trends.
  • 3-Phase power: Built in capability for balanced loads.
  • View graphs and generate reports: Use power analyzer with included Power Log software.