Differential pressure (Price & availability on application)
Design
Per EN 837-3 and ventilation and air-conditioning (VAC)
regulations
Nominal size in mm
110
Accuracy class
±3 %
(±5 % with scale range ≤ 0 ... 125 Pa)
Scale ranges
0 … 50 Pa to 0 … 12,500 Pa
-25 … +25 Pa to -1,500 … +1,500 Pa
further plus/minus ranges on request
Pressure limitation
Steady: Full scale value
Fluctuating: Full scale value
Overpressure safety
20 kPa
Max. working pressure (static pressure)
20 kPa
Permissible temperature
Ambient: -30 ... +80 °C
Medium: -16 … +50 °C
Temperature effect
When the temperature of the measuring system deviates
from the reference temperature (+20 °C):
max. ±0.5 %/10 K of full scale value
Ingress protection
IP 54 per EN 60529 / lEC 529
Design
Per EN 837-3 and ventilation and air-conditioning (VAC)
regulations
Nominal size in mm
110
Accuracy class
±3 %
(±5 % with scale range ≤ 0 ... 125 Pa)
Scale ranges
0 … 50 Pa to 0 … 12,500 Pa
-25 … +25 Pa to -1,500 … +1,500 Pa
further plus/minus ranges on request
Pressure limitation
Steady: Full scale value
Fluctuating: Full scale value
Overpressure safety
20 kPa
Max. working pressure (static pressure)
20 kPa
Permissible temperature
Ambient: -30 ... +80 °C
Medium: -16 … +50 °C
Temperature effect
When the temperature of the measuring system deviates
from the reference temperature (+20 °C):
max. ±0.5 %/10 K of full scale value
Ingress protection
IP 54 per EN 60529 / lEC 529
Applications | For dry, clean, non-aggressive gases, usually air | Fan and blower monitoring | Differential pressure monitoring in filters | Overpressure monitoring in cleanrooms | For very low pressures |
---|---|
Description | Design Per EN 837-3 and ventilation and air-conditioning (VAC) regulations Nominal size in mm 110 Accuracy class ±3 % (±5 % with scale range ≤ 0 ... 125 Pa) Scale ranges 0 … 50 Pa to 0 … 12,500 Pa -25 … +25 Pa to -1,500 … +1,500 Pa further plus/minus ranges on request Pressure limitation Steady: Full scale value Fluctuating: Full scale value Overpressure safety 20 kPa Max. working pressure (static pressure) 20 kPa Permissible temperature Ambient: -30 ... +80 °C Medium: -16 … +50 °C Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.5 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529 |
Model No | A2G-10 |
Special Features | Zero adjustment in front Simple mounting and dismounting Two-part construction (measuring element and case) Optional version with additional electrical output signal (model A2G-15) |