JavaScript seems to be disabled in your browser.For the best experience on our site, be sure to turn on Javascript in your browser.
Licence # QEC25094ISO 9001-2015
DesignTwo independent measuring systems, parallel entries in line
Nominal size in mm80, 100
Accuracy class1.6
Scale ranges0 ... 2.5 to 0 ... 60 bar -1 ... 0 ... +25 bar-1 ... 0 ... +12 bar -1 ... 0 ... +30 bar-1 ... 0 ... +15 bar -1 ... 0 ... +35 bar-1 ... 0 ... +16 bar -1 ... 0 ... +40 barOther scale ranges on requestIn order to ensure a good readability, the differential pressure should be no less than 1/6 of the full scale value.
When ordering state both pressures:a) maximum total pressure applied, b) differential pressure
Pressure limitationSteady: Full scale valueFluctuating: 0.9 x full scale valueShort time: 1.3 x full scale value
Permissible temperatureAmbient: 0 ... +60 °CMedium: +100 °C maximum
Temperature effectWhen the temperature of the measuring system deviates from the reference temperature (+20 °C):max. ±0.4 %/10 K of full scale value