Bourdon tube pressure (Price & availability on application)

Design
EN 837-1

Nominal size in mm
100, 160

Accuracy class
1.0

Scale ranges
0 ... 0.6 to 0 ... 1,000 bar
or all other equivalent vacuum or combined pressure and vacuum ranges

Pressure limitation
Steady: full scale value
Fluctuating: 0.9 x full scale value
Short time: 1.3 x full scale value

Permissible temperature
Ambient: -40 … +60 °C
Medium: +80 °C maximum

Temperature effect
When the temperature of the measuring system deviates from the reference temperature (+20 °C):
max. ±0.4 %/10 K of full scale value

Ingress protection
IP 54 per EN 60529 / lEC 529
Product Description

Details

Design EN 837-1 Nominal size in mm 100, 160 Accuracy class 1.0 Scale ranges 0 ... 0.6 to 0 ... 1,000 bar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Permissible temperature Ambient: -40 … +60 °C Medium: +80 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
Additional Information

Additional Information

Applications Sturdy industrial pressure gauge designed in compliance with the operational safety requirements of EN 837-1, BS 1780 and ASME B 40.1 | Reliable pressure gauge for the machine and plant construction industry as well as domestic technology | For gaseous and liquid media that are not highly viscous or crystallising and will not attack copper alloy parts | Proven in refrigeration technologycontent
Description Design EN 837-1 Nominal size in mm 100, 160 Accuracy class 1.0 Scale ranges 0 ... 0.6 to 0 ... 1,000 bar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Permissible temperature Ambient: -40 … +60 °C Medium: +80 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
Model No 212.20, industrial series
Special Features Long service life, robust | Cost-effective and reliable | To combine with WIKA diaphragm seals | German Lloyd and Gosstandart approval | Scale ranges up to 0 … 1,000 bar
Specification