JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Nominal size in mm100, 160
Accuracy classModel 532.51 NS 160: 0.6Model 532.52: 1.0Model 532.53: 1.6Model 532.54: 2.5The measuring accuracy is ensured for fluctuations in atmospheric pressure between 955 and 1,065 mbar (min. and max. of atmospheric pressure).
Scale ranges0 ... 25 mbar to 0 ... 25 bar absolute pressure
Pressure limitationSteady: Full scale valueFluctuating: 0.9 x full scale value
Overpressure safetyMinimum 1 bar absolute pressure (atmospheric pressure), in addition 10 x full scale value, max. 25 bar absolute pressure
Permissible temperatureAmbient: -20 ... +60 °CMedium: +100 °C maximum
Temperature effectWhen the temperature of the measuring system deviates from the reference temperature (+20 °C):max. ±0.8 %/10 K of full scale value
Ingress protectionIP 54 per EN 60529 / lEC 529