  • Bourdon tube pressure gaugeLower mount, standard (Price & availability on application)

    Bourdon tube pressure gaugeLower mount, standard (Price & availability on application)

    Design EN 837-1 Nominal size in mm 40, 50, 63, 80, 100 and 160 Accuracy class 2.5 Scale ranges 0 ... 0.6 to 0 ... 400 bar (NS 160: max. 40 bar) or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value Permissible temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span
  • Bourdon tube pressure gaugeTest gauge series, class (Price & availability on application)

    Bourdon tube pressure gaugeTest gauge series, class (Price & availability on application)

    Design EN 837-1 Nominal size in mm 160 Accuracy class 0.6 Scale ranges 0 ... 0.6 to 0 ... 600 bar or all other equivalent vacuum or combined pressure and vacuum ranges Adjustment medium ≤ 25 bar: Gas > 25 bar: Liquid Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Permissible temperature Ambient: -40 … +60 °C Medium: +80 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
  • Bourdon tube pressure gaugeTest gauge series, class (Price & availability on application)

    Bourdon tube pressure gaugeTest gauge series, class (Price & availability on application)

    Design EN 837-1 Nominal size in mm 250 Accuracy class 0.6 Scale ranges Model 311.11: 0 ... 0.6 to 0 ... 600 bar Model 331.11: 0 ... 0.6 to 0 ... 1,600 bar or all other equivalent vacuum or combined pressure and vacuum ranges Adjustment medium ≤ 25 bar: Gas > 25 bar: Liquid Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Permissible temperature Ambient: -40 ... +60 °C Medium: +80 °C maximum (model 311.11) +200 °C maximum (model 331.11) Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): Max. ±0.4 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
  • Bourdon tube pressure gaugeTest gauge series, class (Price & availability on application)

    Bourdon tube pressure gaugeTest gauge series, class (Price & availability on application)

    Design per EN 837-1, including transport case and acceptance test certificate (individual listing of the calibration points) Nominal size in mm 250 Accuracy class 0.1 Scale ranges 0 ... 1.0 to 0 ... 1,600 bar or all other equivalent vacuum or combined pressure and vacuum ranges Adjustment medium ≤ 25 bar: Gas > 25 bar: Oil Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Permissible temperature Ambient: -20 … +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): Max. ±0.1 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
  • Capsule Pressure (Price & availability on application)

    Capsule Pressure (Price & availability on application)

    Design EN 837-3 Nominal size in mm 50, 63 Accuracy class 1.6 Scale ranges NS 50: 0 ... 60 mbar to 0 ... 600 mbar NS 63: 0 ... 25 mbar to 0 ... 600 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Operating temperature Ambient: -20 ... +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.6 %/10 K of full scale value Ingress protection IP 32 per EN 60 529 / lEC 529
  • Capsule pressure (Price & availability on application)

    Capsule pressure (Price & availability on application)

    Design EN 837-3 Nominal size in mm 63, 100, 160 Accuracy class 1.6 Scale ranges NS 63: 0 ... 25 mbar to 0 ... 600 mbar NS 100: 0 ... 10 mbar to 0 ... 600 mbar NS 160: 0 ... 6 mbar to 0 ... 600 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Permissible temperature Ambient: -20 … +60 °C Medium: +100 °C maximum + 80 °C maximum (with NS 100 and 160 back mount) Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): Max. ±0.6 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
  • Capsule Pressure Gauges, Square and Edgewise Panel,Mounting (Price & availability on application)

    Capsule Pressure Gauges, Square and Edgewise Panel,Mounting (Price & availability on application)

    Design DIN 43 700 Nominal size in mm 72 x 72, 96 x 96, 144 x 144 and 144 x 72 Accuracy class 1.6 Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Operating temperature Ambient: -20 ... +60 °C Medium: +100 °C maximum Temperature effect When temperature of the measuring system deviates from reference temperature (+20 °C): max. ± 0.6 % / 10 K of true scale value
  • Capsule Pressure (Price & availability on application)

    Capsule Pressure (Price & availability on application)

    Design EN 837-3 Nominal size in mm 50, 63 Accuracy class 2.5 Scale ranges 0 ... 60 mbar to 0 ... 1,000 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Operating temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.6 %/10 K of full scale value Ingress protection IP 53 per EN 60 529 / IEC 529
  • Capsule Pressure GaugesTest Gauge Series, Class (Price & availability on application)

    Capsule Pressure GaugesTest Gauge Series, Class (Price & availability on application)

    Design EN 837-3 Nominal size in mm 160 Accuracy class 0.6 Scale ranges 0 ... 10 mbar to 0 ... 600 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Operating temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.6 %/10 K of full scale value Ingress protection IP 54 per EN 60 529 / lEC 529
  • Capsule pressure gauge,test gauge series, class 0.1 and (Price & availability on application)

    Capsule pressure gauge,test gauge series, class 0.1 and (Price & availability on application)

    Design Following EN 837-3, with measuring cell underneath the case, class 0.1 instruments with transport case and acceptance test certificate (individual listing of the calibration points) Nominal size in mm 250 Accuracy class 0.1 and 0.25 Scale ranges Class 0.1: 0 ... 25 to 0 ... 400 mbar Class 0.25: 0 ... 6 to 0 ... 400 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Adjustment medium Gas Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Permissible temperature Ambient: -20 … +60 °C Medium: +60 °C maximum Temperature effect The indicated class accuracy applies to a room temperature of +20 °C. Temperature-related zero offsets can be corrected by means of the zero adjustment. Ingress protection IP 54 per EN 60529 / lEC 529
  • Differential Pressure (Price & availability on application)

    Differential Pressure (Price & availability on application)

    Design Two independent measuring systems, vee entry 60° Nominal size in mm 100, 160 Accuracy class 1.6 Scale ranges 0 ... 0.6 to 0 ... 60 bar Scale range must be selected in relation to the highest total pressure applied! In heating plants with circulating pumps, the overall pressure is usually defined as equal to the hydrostatic pressure plus the pump pressure. In order to ensure a good readability, the pressure differential to be indicated should be no less than 1/6 of the full scale range. When ordering please state both pressures: a) maximum pressure applied, b) differential pressure Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: full scale value Operating temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 33 per EN 60 529 / lEC 529
  • Differential Pressure Gauges with Bourdon Tube, Parallel (Price & availability on application)

    Differential Pressure Gauges with Bourdon Tube, Parallel (Price & availability on application)

    Design 2 independent measuring systems, parallel entries in line Nominal size in mm 100, 160 Accuracy class 1.6 Scale ranges 0 ... 0.6 to 0 ... 1000 bar Scale range must be selected in relation to the highest total pressure applied! In heating plants with circulating pumps, the overall pressure is usually defined as equal to the hydrostatic pressure plus the pump pressure. In order to ensure a good readability, the pressure differential to be indicated should be no less than 1/6 of the full scale range. When ordering please state both pressures: a) maximum pressure applied, b) differential pressure Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Operating temperature Ambient: -20 ... +60 °C Medium: Model 711.12: +60 °C maximum (soft soldered); +100 °C maximum (brazed) Model 731.12: +200 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 33 per EN 60 529 / lEC 529
  • Differential pressure gauge with capsule (Price & availability on application)

    Differential pressure gauge with capsule (Price & availability on application)

    Design For very low differential pressures, DT - GM 87 10 226 Nominal size in mm Model 716.11: NS 63, 100, 160 Model 736.11: NS 100, 160 Accuracy class 1.6 Scale ranges Model 716.11: NS 63: 0 ... 16 to 0 ... 400 mbar NS 100: 0 ... 10 to 0 ... 250 mbar NS 160: 0 ... 6 to 0 ... 250 mbar Model 736.11: NS 100: 0 ... 16 to 0 ... 250 mbar NS 160: 0 ... 1.6 to 0 ... 250 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Overpressure safety Full scale value Max. working pressure (static pressure) NS 63: 400 mbar NS 100, 160: 250 mbar Permissible temperature Ambient: -20 ... +60 °C Medium: +70 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.5 %/10 K of full scale value Ingress protection IP 66 per EN 60529 / lEC 529
  • Differential Pressure (Price & availability on application)

    Differential Pressure (Price & availability on application)

    Design Small, compact version WIKA trade pattern DT-GM 87 10 226 Nominal size in mm 80 Accuracy class 4.0: scale ranges 0 ... 16 mbar and 0 ... 25 mbar 2.5: scale ranges 0 ... 40 mbar to 0 ... 600 mbar Scale ranges 0 ... 16 mbar to 0 ... 600 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: full scale value Fluctuating: full scale value Overpressure safety Either side max. 16 bar Max. working pressure (static pressure) 16 bar Operating temperature Ambient: -15 ... +60 °C Medium: +70 °C maximum Temperature effect When temperature of the measuring system deviates from reference temperature (+20 °C): max. ±0.5 %/10 K of true scale value Ingress protection lP 66 per EN 60 529 / lEC 529
  • Differential Pressure GaugesWith Integrated Working Pressure (Price & availability on application)

    Differential Pressure GaugesWith Integrated Working Pressure (Price & availability on application)

    These differential pressure gauges are particularly intended for the monitoring of differential pressures in filter systems, pumps and pipeline systems in the heating, ventilation and air-conditioning sector, technical building equipment and in the water management industry. Apart from the display of the differential pressure, these applications require, as a rule, the display of the current working pressure. For this reason, a working pressure gauge is integrated in the DELTA-plus differential pressure gauge as a standard feature. An additional measuring point involving additional expenses for piping and mounting is thus no longer required. The white dial of the working pressure gauge distinctly stands out against the blue background of the display of the differential pressure gauge, thus enabling a quick and safe reading of both measurement parameters. The ranges of 0 ... 250 mbar up to 0 ... 25 bar provide the measuring ranges, which are required in many different applications. The sturdy and compact design of the differential pressure gauge makes it possible to use it even under tough industrial ambient conditions.
  • Differential pressure (Price & availability on application)

    Differential pressure (Price & availability on application)

    These high-quality gauges are characterised by their compact and durable construction and are primarily for use in level measurement on liquid gas tanks. All the standard cryogenics tank sizes are covered using only 4 different measuring cells. As a result of the large measuring-range overlap of the respective measuring cells, the gauge installed on the tank can be adjusted to match a whole variety of gases such as Ar, O2, N2 or CO2, with a full-scale deflection over a complete 270 degree sweep. The span adjustment is accessible from outside and does not affect the zero point. The mechanical display and the optional electrical output signal are calibrated simultaneously and easily. An optional connectable valve block with working pressure display makes the central measurement of both level and working pressure possible in the one instrument. The level display can be supplied with an optional, integrated 4 … 20 mA, 2-wire transmitter. Limit signal transmitters for level and working pressure, as well as a transmitter for the working pressure can be retrofitted onsite. The standard connection distance between the process connections of 37 mm can be adapted to custom connection distances of 31 mm or 54 mm using connection adapters.
  • Differential pressure (Price & availability on application)

    Differential pressure (Price & availability on application)

    Design Per EN 837-3 and ventilation and air-conditioning (VAC) regulations Nominal size in mm 110 Accuracy class ±3 % (±5 % with scale range ≤ 0 ... 125 Pa) Scale ranges 0 … 50 Pa to 0 … 12,500 Pa -25 … +25 Pa to -1,500 … +1,500 Pa further plus/minus ranges on request Pressure limitation Steady: Full scale value Fluctuating: Full scale value Overpressure safety 20 kPa Max. working pressure (static pressure) 20 kPa Permissible temperature Ambient: -30 ... +80 °C Medium: -16 … +50 °C Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.5 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
  • Bourdon tube pressure gauge,edgewise panel (Price & availability on application)

    Bourdon tube pressure gauge,edgewise panel (Price & availability on application)

    Design DIN 437002 Nominal sizes in mm 144 x 72, 144 x 144, 96 x 96, 72 x 72 Accurancy class Class 1.0: NS 144 x 72, 144 x 144, 96 x 96 Class 1.6: NS 72 x 72, 96 x 96 Scale ranges NS 144 x 72, 144 x 144, 96 x 96: 0 ... 0.6 to 0 ... 1,000 bar NS 72 x 72: 0 ... 0.6 to 0 ... 400 bar or all other equivalent vacuum or combined pressure and vacuum ranges Permissible temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum (soft soldered); +100 °C maximum (brazed) Pressure limitation NS 144 x 72, 144 x 144, 96 x 96 Steady: Full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value NS 72 x 72 Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 42 per EN 60529 / lEC 529
  • Bourdon tube pressure gauge,industrial series, measuring system Cu-(Price & availability on application)

    Bourdon tube pressure gauge,industrial series, measuring system Cu-(Price & availability on application)

    Nominal size in mm 250 Accuracy class 1.0 Scale ranges 0 ... 0.6 to 0 ... 1600 bar or all other equivalent vacuum or combined pressure and vacuum ranges
  • Bourdon tube pressure (Price & availability on application)

    Bourdon tube pressure (Price & availability on application)

    Design EN 837-1 Nominal size in mm 100, 160 Accuracy class 1.0 Scale ranges 0 ... 0.6 to 0 ... 1,000 bar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Permissible temperature Ambient: -40 … +60 °C Medium: +80 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
  • Bourdon tube pressure (Price & availability on application)

    Bourdon tube pressure (Price & availability on application)

    Design ISO 5171 Nominal size in mm 40, 50, 63 Accuracy class 2.5 Scale ranges Welding engineering standard ranges for oxygen and acetylene to ISO 5171, as well as 0 ... 1 to 0 ... 400 bar to EN 837-1 Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value Permissible temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span
  • Bourdon tube pressure gaugeBack mount, standard (Price & availability on application)

    Bourdon tube pressure gaugeBack mount, standard (Price & availability on application)

    Design EN 837-1 Nominal size in mm 40, 50, 63, 80 and 100 Accuracy class 2.5 Scale ranges 0 ... 0.6 to 0 ... 400 bar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value Permissible temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span
  • Miniature bourdon tube pressure gaugeBack mount, standard (Price & availability on application)

    Miniature bourdon tube pressure gaugeBack mount, standard (Price & availability on application)

    Nominal size in mm 27 Accuracy class 4.0 Scale ranges Low pressure: 0 ... 4 to 0 ... 25 bar High pressure: 0 ... 100 to 0 ... 400 bar or all other equivalent pressure ranges Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value Permissible temperature Ambient: -20 … +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span
  • Bourdon tube pressure (Price & availability on application)

    Bourdon tube pressure (Price & availability on application)

    Nominal size in mm 63 and 80 Accuracy class pm ≤ 4 bar: ± 0.08 bar 4 bar < pm ≤ 10 bar: ± 0.16 bar pm > 10 bar: ± 0.25 bar (pm ... measured pressure) Error limits are met within a temperature range between 15 °C and 25 °C Scale ranges 0 ... 4 bar 0 ... 10 bar 0 ... 12 bar (only NS 80) Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: full scale value Operating temperature Ambient: -20 … +60 °C Medium: +40 °C maximum Storage: -40 … +70 °C Temperature effect When the temperature of the measuring system deviates from the reference temperature range (-10 ... +40 °C): pm ≤ 4 bar: 0.1 % of 4 bar 4 bar < pm ≤ 10 bar: 0.05 % of 10 bar pm > 10 bar: 0.05 % of the full scale value (pm ... measured pressure) Ingress protection IP 44 per EN 60529 / lEC 529
  • Bourdon tube pressure (Price & availability on application)

    Bourdon tube pressure (Price & availability on application)

    Design EN 837-1 Nominal size in mm 40, 50 and 63 Accuracy class 2.5 Scale ranges 0 ... 0.6 to 0 ... 400 bar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value Permissible temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span
  • Bourdon tube pressure gaugeBack mount, panel mounting series with spring (Price & availability on application)

    Bourdon tube pressure gaugeBack mount, panel mounting series with spring (Price & availability on application)

    Design EN 837-1 Nominal size in mm 40, 50, 63, 80 Accuracy class 2.5 Scale ranges 0 ... 2.5 to 0 ... 400 bar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value Permissible temperature Ambient: -20 … +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span
  • Pressure gauge with spiral (Price & availability on application)

    Pressure gauge with spiral (Price & availability on application)

    Nominal size in mm 36, 41 Accuracy class 2.5 Scale ranges 0 ... 160 to 0 ... 400 bar Pressure limitation Steady: 3/4 x full scale value Short time: Full scale value Permissible temperature Ambient: -20 … +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span
  • Bourdon tube pressure gauge,industrial (Price & availability on application)

    Bourdon tube pressure gauge,industrial (Price & availability on application)

    Design EN 837-1 Nominal size in mm 80 Accuracy class 1.6 Scale ranges Model 112.28: 0 ... 0.6 to 0 ... 40 bar Model 132.28: 0 ... 1 to 0 ... 40 bar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Permissible temperature Ambient: -40 ... +60 °C Medium: +60 °C maximum (model 112.28) +200 °C maximum (model 132.28) Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): Max. ±0.4 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
  • Bourdon tube pressure gauge,liquid filling, plastic (Price & availability on application)

    Bourdon tube pressure gauge,liquid filling, plastic (Price & availability on application)

    Design EN 837-1 Nominal size in mm 40, 50 and 63 Accuracy class 2.5 Scale ranges 0 ... 1 to 0 ... 400 bar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value Permissible temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span Ingress protection IP 65 per EN 60529 / lEC 529
  • Bourdon tube pressure (Price & availability on application)

    Bourdon tube pressure (Price & availability on application)

    Design EN 837-1 Nominal size in mm 40, 80, 100 Accuracy class NS 40: 2.5 NS 80, 100: 1.6 Scale ranges 0 ... 1 to 0 ... 400 bar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value Permissible temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span Ingress protection IP 65 per EN 60529 / lEC 529
  • Bourdon tube pressure (Price & availability on application)

    Bourdon tube pressure (Price & availability on application)

    Design EN 837-1 Nominal size in mm 50, 63, 100 Accuracy class NS 50, 63: 1.6 NS 100: 1.0 Scale ranges NS 50: 0 ... 1 to 0 ... 400 bar NS 63, 100: 0 ... 0.6 to 0 ... 1000 bar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation NS 50, 63: Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value NS 100: Steady: Full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Permissible temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): Max. ±0.4 %/10 K of the span Ingress protection IP 65 per EN 60529 / lEC 529
  • Bourdon tube pressure gauge,with liquid filling and forged brass (Price & availability on application)

    Bourdon tube pressure gauge,with liquid filling and forged brass (Price & availability on application)

    Nominal size 63 and 100 mm Accuracy class NS 63:1.6 NS 100: 1.0 Scale range NS 50: 0 ... 1 up to 0 ... 600 bar NS 63, 80, 100: 0 ... 0,6 up to 0 ... 1000 bar Or other equivalent units of pressure or vacuum.
  • Bourdon tube pressure gauges,mining (Price & availability on application)

    Bourdon tube pressure gauges,mining (Price & availability on application)

    Nominal size in mm 50 Accuracy class 2,5 Scale range 0 ... 600 bar
  • Bourdon tube pressure gauge, with plastic (Price & availability on application)

    Bourdon tube pressure gauge, with plastic (Price & availability on application)

    Nominal size in mm Model 101.00: NS 40 Model 101.12: NS 27 Accuracy class NS 40: 2.5 % NS 27: 4 % Scale ranges 0 ... 4, 0 ... 6 bar Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value Permissible temperature Ambient: 0 … +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span
  • Thermomanometer for pressure and temperature (Price & availability on application)

    Thermomanometer for pressure and temperature (Price & availability on application)

    Nominal size in mm 40, 42, 52 Working ranges Pressure: Steady: 3/4 x full scale value Short time: Full scale value Temperature: Full scale value Measuring elements Bourdon tube, Cu-alloy Connection Cu-alloy, back mount (BM) Pressure: Male thread G 1/4 B (rotatable) with capillary Temperature: Capillary, with sensor D6, plastic covered Case Plastic, black, with front flange and lateral snap-fit provisions for panel mounting Movement (pressure indication) Cu-alloy Dial Plastic, white, black lettering Pointer Plastic, black Window Plastic, crystal-clear Options Other scale ranges Capillary lengths (pressure, temperature), max. 5 m Capillary (pressure) plastic covered Other temperature sensor dimensions Other pressure connections Special scales
  • Bourdon tube pressure gaugeSafety (Price & availability on application)

    Bourdon tube pressure gaugeSafety (Price & availability on application)

    Design ISO 5171 Nominal size in mm 50 Accuracy class 2.5 Scale range 0 ... 2.5 to 0 ... 400 bar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value Permissible temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span
  • Inclined tube (Price & availability on application)

    Inclined tube (Price & availability on application)

    Accuracy 5 Pa / 25 Pa Scale range 0 … 600 Pa Max. pressure 200 kPa (2 bar) Permissible temperature Ambient: -40 … +60 °C Operation: -40 … +60 °C Ingress protection IP 54 per EN 60529 / lEC 529 Weight 420 g