  • Bourdon tube pressure (Price & availability on application)

    Bourdon tube pressure (Price & availability on application)

    Design EN 837-1 Nominal size in mm 40, 50, 63 Accuracy class 2.5 Scale ranges NS 40 and 50: 0 ... 1 to 0 ... 600 bar NS 63: 0 ... 1 to 0 ... 1,000 bar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value Permissible temperature Ambient: -40 … +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
  • Capsule pressure gauge,Stainless Steel Series, High Overpressure (Price & availability on application)

    Capsule pressure gauge,Stainless Steel Series, High Overpressure (Price & availability on application)

    Nominal size in mm 100, 160 Accuracy class 1.6 Scale ranges 0 ... 2.5 to 0 ... 100 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Overpressure safety 50 x full scale value, max. 7 bar Operating temperature Ambient: -20 ... +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.6 %/10 K of full scale value Ingress protection lP 54 per EN 60 529 / lEC 529
  • Capsule Pressure (Price & availability on application)

    Capsule Pressure (Price & availability on application)

    Design EN 837-3 Nominal size in mm 50, 63 Accuracy class 1.6 Scale ranges NS 50: 0 ... 60 mbar to 0 ... 600 mbar NS 63: 0 ... 25 mbar to 0 ... 600 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Operating temperature Ambient: -20 ... +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.6 %/10 K of full scale value Ingress protection IP 32 per EN 60 529 / lEC 529
  • Capsule Pressure GaugesStainless Steel Series(Price & availability on application)

    Capsule Pressure GaugesStainless Steel Series(Price & availability on application)

    Design EN 837-3 Nominal size in mm 63, 100, 160 Accuracy class 1.6 Scale ranges NS 63: 0 ... 40 mbar to 0 ... 600 mbar NS 100: 0 ... 16 mbar to 0 ... 600 mbar NS 160: 0 ... 2.5 mbar to 0 ... 600 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Operating temperature Ambient: -20 ... +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.6 %/10 K of full scale value Ingress protection IP 54 per EN 60 529 / IEC 529 (with liquid filling IP 65)
  • Capsule Pressure Gauges, Square and Edgewise Panel,Mounting Series (Price & availability on application)

    Capsule Pressure Gauges, Square and Edgewise Panel,Mounting Series (Price & availability on application)

    Design DIN 43 700 Nominal size in mm 72 x 72, 96 x 96, 144 x 144 and 144 x 72 Accuracy class 1.6 Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Operating temperature Ambient: -20 ... +60 °C Medium: +100 °C maximum Temperature effect When temperature of the measuring system deviates from reference temperature (+20 °C): max. ± 0.6 % / 10 K of true scale value
  • Capsule Pressure GaugesTest Gauge Series, Class 0.6 (Price & availability on application)

    Capsule Pressure GaugesTest Gauge Series, Class 0.6 (Price & availability on application)

    Design EN 837-3 Nominal size in mm 160 Accuracy class 0.6 Scale ranges 0 ... 10 mbar to 0 ... 600 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Operating temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.6 %/10 K of full scale value Ingress protection IP 54 per EN 60 529 / lEC 529
  • Differential Pressure Gauges with Bourdon Tube, Parallel Entry (Price & availability on application)

    Differential Pressure Gauges with Bourdon Tube, Parallel Entry (Price & availability on application)

    Design 2 independent measuring systems, parallel entries in line Nominal size in mm 100, 160 Accuracy class 1.6 Scale ranges 0 ... 0.6 to 0 ... 1,000 bar Scale range must be selected in relation to the highest total pressure applied! In heating plants with circulating pumps, the overall pressure is usually defined as equal to the hydrostatic pressure plus the pump pressure. In order to ensure a good readability, the pressure differential to be indicated should be no less than 1/6 of the full scale range. When ordering please state both pressures: a) maximum pressure applied, b) differential pressure Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Operating temperature Ambient: -20 ... +60 °C Medium: Model 711.12: +60 °C maximum (soft soldered) +100 °C maximum (brazed) Model 731.12: +200 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 33 per EN 60 529 / lEC 52
  • Differential pressure gauge with capsule element (Price & availability on application)

    Differential pressure gauge with capsule element (Price & availability on application)

    Design For very low differential pressures, DT - GM 87 10 226 Nominal size in mm Model 716.11: NS 63, 100, 160 Model 736.11: NS 100, 160 Accuracy class 1.6 Scale ranges Model 716.11: NS 63: 0 ... 16 to 0 ... 400 mbar NS 100: 0 ... 10 to 0 ... 250 mbar NS 160: 0 ... 6 to 0 ... 250 mbar Model 736.11: NS 100: 0 ... 16 to 0 ... 250 mbar NS 160: 0 ... 1.6 to 0 ... 250 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Overpressure safety Full scale value Max. working pressure (static pressure) NS 63: 400 mbar NS 100, 160: 250 mbar Permissible temperature Ambient: -20 ... +60 °C Medium: +70 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.5 %/10 K of full scale value Ingress protection IP 66 per EN 60529 / lEC 529
  • Differential pressure gauge with Bourdon tube, parallel entryMeasuring system stainless steel (Price & availability on application)

    Differential pressure gauge with Bourdon tube, parallel entryMeasuring system stainless steel (Price & availability on application)

    These differential pressure gauges are made of highly corrosion-resistant stainless steel and feature an all-metal, all-welded media chamber to ensure long-term leak tightness (no elastomer sealing elements). A high overpressure safety is achieved by the all-metal construction and the close-fitting design of the pressure measuring diaphragm. With its high-grade stainless steel construction and robust design this pressure gauge is geared to chemical and process engineering applications. It is suitable for gaseous or liquid media, also in aggressive ambience. The scale ranges of 0 ... 16 mbar to 0 ... 25 bar are available to meet the requirements of a wide variety of applications.
  • Differential pressure gauge with Bourdon tube, parallel entryMeasuring system stainless steel (Price & availability on application)

    Differential pressure gauge with Bourdon tube, parallel entryMeasuring system stainless steel (Price & availability on application)

    Design Two independent measuring systems, parallel entries in line Nominal size in mm 80, 100 Accuracy class 1.6 Scale ranges 0 ... 2.5 to 0 ... 60 bar -1 ... 0 ... +25 bar -1 ... 0 ... +12 bar -1 ... 0 ... +30 bar -1 ... 0 ... +15 bar -1 ... 0 ... +35 bar -1 ... 0 ... +16 bar -1 ... 0 ... +40 bar Other scale ranges on request In order to ensure a good readability, the differential pressure should be no less than 1/6 of the full scale value. When ordering state both pressures: a) maximum total pressure applied, b) differential pressure Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Permissible temperature Ambient: 0 ... +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value
  • Differential pressure gauge with capsule element,stainless steel series, for low differential pressure,especially for alarm contacts and transmitters (Price & availability on application)

    Differential pressure gauge with capsule element,stainless steel series, for low differential pressure,especially for alarm contacts and transmitters (Price & availability on application)

    Design high overpressure safety, media chamber protected against unauthorised intervention, zero adjustment under pressure load WIKA trade pattern DT - GM 86 08 176 Nominal size in mm 100, 160 Accuracy class 1.6 Scale ranges 0 ... 2.5 to 0 ... 160 mbar or all other equivalent vacuum or combined pressure and vacuum ranges
  • Differential pressure gauge (Price & availability on application)

    Differential pressure gauge (Price & availability on application)

    These differential pressure gauges are made of highly corrosion-resistant stainless steel. A high overpressure safety is achieved by the all-metal construction and the close-fitting design of the pressure measuring diaphragm. With its high-grade stainless steel construction and robust design this pressure gauge is geared to chemical and process engineering applications. It is suitable for gaseous or liquid media, also in aggressive ambience. The wetted parts for these differential pressure gauges are available also in special materials such as Monel, Hastelloy or PTFE. The scale ranges of 0 ... 60 mbar to 0 ... 40 bar are available to meet the requirements of a wide variety of applications.
  • Differential pressure gauges (Price & availability on application)

    Differential pressure gauges (Price & availability on application)

    Model 700.01 is particularly intended for the monitoring of differential pressures even in the case of high working pressures in gas and air preparation and supply systems. Model 700.02, the version with a separation diaphragm, is suitable for liquid media and therefore also for water treatment and supply systems. This piston-type differential pressure gauge offers special advantages due to its compact modular design. For instance an on-the-spot replacement of measuring system and case of indication is possible in retrospect and the Reed contacts can also be retrofitted and adjusted locally. A front surface mounting flange may be retrofitted on model 700.01. Although these models have a high overload capacity either side up to the maximum working pressure, the weight of the standard versions, i.e. approx. 220 g in the case of model 700.01 and approx. 500 g in the case of model 700.02, is extremely low. Therefore, these gauges provide an economical and flexible solution to your measuring task. This compact design with a measuring system of stainless steel enables an optimal price/performance ratio.
  • Bourdon tube pressure gaugeUHP, stainless steel, safety pattern (Price & availability on application)

    Bourdon tube pressure gaugeUHP, stainless steel, safety pattern (Price & availability on application)

    Design EN 837-1 Nominal size in mm 63 Accuracy class 1.6 Scale ranges 0 ... 1 to 0 ... 400 bar (0 ... 15 to 0 ... 6000 psi) or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: full scale value Operating temperature Ambient: -40 ... +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / IEC 529
  • Bourdon tube pressure gaugeHP, stainless steel (Price & availability on application)

    Bourdon tube pressure gaugeHP, stainless steel (Price & availability on application)

    Nominal size 1 ½", 2" Accuracy class NS 1 ½": Grade B per ASME B40.1 NS 2": Grade A per ASME B40.1 Scale ranges 0 ... 1 to 0 ... 700 bar (0 ... 15 to 0 ... 10,000 psi) or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value Permissible temperature Ambient: -40 ... +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
  • Bourdon tube pressure gaugeIndustrial series, NS (Price & availability on application)

    Bourdon tube pressure gaugeIndustrial series, NS (Price & availability on application)

    Design EN 837-1 Nominal size in mm 80 Accuracy class 1.6 Scale ranges Model 112.28: 0 ... 0.6 to 0 ... 40 bar Model 132.28: 0 ... 1 to 0 ... 40 bar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Permissible temperature Ambient: -40 ... +60 °C Medium: +60 °C maximum (model 112.28) +200 °C maximum (model 132.28) Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): Max. ±0.4 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
  • Bourdon tube pressure gaugeStainless steel, safety version, high overpressure (Price & availability on application)

    Bourdon tube pressure gaugeStainless steel, safety version, high overpressure (Price & availability on application)

    Design Safety pattern (Solidfront) referring to EN 837-1 Nominal size 100 and 160 mm Measuring ranges and overpressure ranges Measuring range in bar Overpressure range up to ... bar -1 ... 0 3 0 ... 0.6 2.5 0 ... 1 4 0 ... 1.6 6 0 ... 2.5 10 0 ... 4 16 0 ... 6 25 0 ... 10 40 0 ... 16 60 0 ... 25 80 0 ... 40 100 Accuracy class Measuring range: 1.0 The measuring range end is marked by a triangle Pressure limitation Steady: end value of measuring range Fluctuating: 0.9 x end value of measuring range Short time: Overpressure range Permissible temperature Ambient: -40 ... +60°C without liquid filling -20 ... +60 °C gauges with glycerine filling (Model 233.36 ) Medium: +200 °C maximum without liquid filling +100 °C maximum with liquid filling (Model 233.36 ) Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 % / 10 K of full scale value Ingress protection IP 65 per EN 60529/IEC 529
  • Bourdon Tube Pressure GaugesProcess Gauge, Safety Pattern (Price & availability on application)

    Bourdon Tube Pressure GaugesProcess Gauge, Safety Pattern (Price & availability on application)

    Designali>Per US Standard ASME B 40.1 Nominal size 4 ½" Accuracy class Grade 2A per ASME B 40.1 (corresponds to indication accuracy 0.5 %) Scale ranges 0 ... 0.6 bar to 0 ... 1000 bar (0 ... 10 psi to 0 ... 15000 psi) or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Operating temperature Ambient: -40 ... +65 °C without liquid filling -20 ... +65 °C gauges with glycerine filling Medium: +100 °C maximum (Please look at the data sheet) Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 54 per EN 60 529 / IEC 529 (with liquid filling IP 65)
  • Bourdon tube pressure gaugeStainless steel, safety (Price & availability on application)

    Bourdon tube pressure gaugeStainless steel, safety (Price & availability on application)

    Design EN 837-1 Nominal size in mm 63, 100, 160 Accuracy class NS 63: 1.6 NS 100, 160: 1.0 Scale ranges NS 63: 0 ... 1 to 0 ... 1,000 bar NS 100: 0 ... 0.6 to 0 ... 1,000 bar NS 160: 0 ... 0.6 to 0 ... 1,600 bar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation NS 63: Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value NS 100, 160: Steady: Full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Permissible temperature Ambient: -40 ... +60 °C without liquid filling -20 ... +60 °C gauges with glycerine filling (Model 233.30) Medium: +200 °C maximum without liquid filling +100 °C maximum with liquid filling (Model 233.30) Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 65 per EN 60529 / lEC 529 (gauges with back mount: IP 55)
  • Bourdon tube pressure gauge,stainless steel series, without/with liquid (Price & availability on application)

    Bourdon tube pressure gauge,stainless steel series, without/with liquid (Price & availability on application)

    Nominal size in mm 63, 100, 160 Accuracy class NS 63: 1.6 NS 100, 160: 1.0 Scale ranges NS 63: 0 ... 1 to 0 ... 1000 bar NS 100: 0 ... 0.6 to 0 ... 1000 bar NS 160: 0 ... 0.6 to 0 ... 1600 bar or all other equivalent vacuum or combined pressure and vacuum ranges
  • Bourdon tube pressure gauge,stainless steel, high pressure, safety pattern version,without/with liquid (Price & availability on application)

    Bourdon tube pressure gauge,stainless steel, high pressure, safety pattern version,without/with liquid (Price & availability on application)

    Nominal size 160 mm Accuracy class 1.0 Scale ranges 0 ... 2500 to 0 ... 7000 bar
  • Bourdon tube pressure gaugeIndustrial series, NS (Price & availability on application)

    Bourdon tube pressure gaugeIndustrial series, NS (Price & availability on application)

    Design EN 837-1 Nominal size in mm 250 Accuracy class 1.0 Scale ranges 0 ... 0.6 to 0 ... 1,600 bar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Permissible temperature Ambient: -40 ... +60 °C Medium: +80 °C maximum (model 211.11) +200 °C maximum (model 231.11) Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): Max. ±0.4 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
  • Bourdon tube pressure gaugeEdgewise panel (Price & availability on application)

    Bourdon tube pressure gaugeEdgewise panel (Price & availability on application)

    Design DIN 43700 Nominal sizes in mm 144 x 72 144 x 144 96 x 96 72 x 72 Accurancy class Class 1.0: NS 144 x 72, 144 x 144, 96 x 96 Class 1.6: NS 72 x 72, 96 x 96 Scale ranges NS 144 x 72, 144 x 144, 96 x 96: 0 ... 0.6 to 0 ... 1000 bar NS 72 x 72: 0 ... 0.6 to 0 ... 400 bar or all other equivalent vacuum or combined pressure and vacuum ranges Permissible temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum (soft soldered); +100 °C maximum (brazed) Pressure limitation NS 144 x 72, 144 x 144, 96 x 96 Steady: Full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value NS 72 x 72 Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 42 per EN 60529 / lEC 529
  • Bourdon tube pressure gaugeTest gauge series, class (Price & availability on application)

    Bourdon tube pressure gaugeTest gauge series, class (Price & availability on application)

    Design EN 837-1 Nominal size in mm 160 Accuracy class 0.6 Scale ranges 0 ... 0.6 to 0 ... 1,600 bar or all other equivalent vacuum or combined pressure and vacuum ranges Adjustment medium ≤ 25 bar: Gas > 25 bar: Liquid Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Permissible temperature Ambient: -40 ... +60 °C without liquid filling -20 ... +60 °C gauges with glycerine filling (Model 333.50) Medium: +200 °C maximum without liquid filling +100 °C maximum with liquid filling (Model 333.50) Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 65 per EN 60529 / lEC 529
  • Bourdon Tube Pressure GaugesTest Gauge Series, Safety Pattern Version, Class (Price & availability on application)

    Bourdon Tube Pressure GaugesTest Gauge Series, Safety Pattern Version, Class (Price & availability on application)

    Design EN 837-1 Nominal size in mm 160 Accuracy class 0.6 Scale ranges 0 ... 0.6 to 0 ... 1,600 bar or all other equivalent vacuum or combined pressure and vacuum ranges Adjustment medium ≤ 25 bar: gas > 25 bar: liquid (inside of measuring system dried afterwards) Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Operating temperature Ambient: -40 ... +60 °C without liquid filling -20 ... +60 °C gauges with glycerine filling Medium: +200 °C maximum without liquid filling +100 °C maximum with liquid filling Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 65 per EN 60 529 / IEC 529
  • Bourdon tube pressure gaugeTest gauge, safety version, class (Price & availability on application)

    Bourdon tube pressure gaugeTest gauge, safety version, class (Price & availability on application)

    Design EN 837-1 Nominal size in mm 160 Accuracy class 0.6 Scale ranges 0 ... 0.6 to 0 ... 600 bar or all other equivalent vacuum or combined pressure and vacuum ranges Adjustment medium ≤ 25 bar: Gas > 25 bar: Liquid Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Permissible temperature Ambient: -40 … +60 °C Medium: +200 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): Max. ±0.4 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
  • Bourdon Tube Caisson Pressure GaugesRoom Pressure (Price & availability on application)

    Bourdon Tube Caisson Pressure GaugesRoom Pressure (Price & availability on application)

    Nominal size in mm 160 Accuracy class 1.0 Scale ranges 0 ... 0.6 to 0 ... 16 bar Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Operating temperature Ambient: -20 … +60 °C Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 55 per EN 60 529 / lEC 529
  • Bourdon tube pressure gauge,UHP, stainless steel (Price & availability on application)

    Bourdon tube pressure gauge,UHP, stainless steel (Price & availability on application)

    Nominal size 1 ½", 2" Accuracy class NS 1 ½": Grade B according to ASME B40.1 NS 2": Grade A according to ASME B40.1 Scale ranges 0 ... 1 to 0 ... 400 bar (0 ... 15 to 0 ... 6000 psi) or other equivalent units of pressure or vacuum
  • Differential pressure gauge (Price & availability on application)

    Differential pressure gauge (Price & availability on application)

    These high-quality gauges are characterised by their compact and robust design and are primarily used for level measurement on liquid gas tanks. With only 4 different measuring cells all usual tank sizes in cryotechnology are covered. As a result of the large measuring range overlap of the respective measuring cells, the gauge installed on the tank can be adjusted to match a whole variety of gases such as Ar, O2, N2 or CO2, with a full-scale deflection over a complete 270 degree sweep. The span adjustment is accessible from outside and does not affect the zero point. The mechanical display and the optional electrical output signal are calibrated simultaneously and easily. An optional valve manifold for flange mounting with working pressure indication makes the central measurement of both level and working pressure possible in the one instrument. The level display can be supplied with an optional, integrated 4 … 20 mA, 2-wire transmitter. Switch contacts for level and working pressure, as well as a transmitter for the working pressure can be retrofitted on site. The standard centre distance of 37 mm between the process connections can be adapted to a custom centre distance of 31 mm or 54 mm using adapters for flange mounting.