Capsule Pressure GaugesStainless Steel Series(Price & availability on application)

Design EN 837-3 Nominal size in mm 63, 100, 160 Accuracy class 1.6 Scale ranges NS 63: 0 ... 40 mbar to 0 ... 600 mbar NS 100: 0 ... 16 mbar to 0 ... 600 mbar NS 160: 0 ... 2.5 mbar to 0 ... 600 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Operating temperature Ambient: -20 ... +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.6 %/10 K of full scale value Ingress protection IP 54 per EN 60 529 / IEC 529 (with liquid filling IP 65)
Design EN 837-3 Nominal size in mm 63, 100, 160 Accuracy class 1.6 Scale ranges NS 63: 0 ... 40 mbar to 0 ... 600 mbar NS 100: 0 ... 16 mbar to 0 ... 600 mbar NS 160: 0 ... 2.5 mbar to 0 ... 600 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Operating temperature Ambient: -20 ... +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.6 %/10 K of full scale value Ingress protection IP 54 per EN 60 529 / IEC 529 (with liquid filling IP 65)
More Information
Applications With liquid filled case for applications with high dynamic pressure pulsations or vibrations | For gaseous, dry and aggressive media, also in aggressive ambience | Process industry: chemical/petro-chemical, pharmaceutical, biotechnology, machine and power generation industries
Description Design EN 837-3 Nominal size in mm 63, 100, 160 Accuracy class 1.6 Scale ranges NS 63: 0 ... 40 mbar to 0 ... 600 mbar NS 100: 0 ... 16 mbar to 0 ... 600 mbar NS 160: 0 ... 2.5 mbar to 0 ... 600 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value Operating temperature Ambient: -20 ... +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.6 %/10 K of full scale value Ingress protection IP 54 per EN 60 529 / IEC 529 (with liquid filling IP 65)
Model No 632.50/633.50, without/with Liquid Filling
Special Features Zero adjustment in front | All stainless steel construction | Special connection location on request | Low scale ranges from 0 ... 2.5 mbar