Capsule Pressure Gauges, Square and Edgewise Panel, Mounting Series

Capsule Pressure Gauges, Square and Edgewise Panel, Mounting Series

Design
DIN 43700

Nominal size in mm
72 x 72, 96 x 96, 144 x 144 and 144 x 72

Accuracy class
1.6

Pressure limitation
Steady: Full scale value
Fluctuating: 0.9 x full scale value

Operating temperature
Ambient: -20 ... +60 °C
Medium: +100 °C maximum

Temperature effect
When the temperature of the measuring system deviates from the reference temperature (+20 °C):
max. ± 0.6 %/10 K of full scale value

More Information
Applications For gaseous. dry and non-aggressive media that will not attack copper alloy parts Model 614.11: Measuring system copper alloy Model 634.11: Measuring system stainless steel, also for aggressive media
Model No 614.11, 634.11
Special Features
  • Low scale ranges from 0 ... 2.5 mbar
  • Panel mounting
  • Zero adjustment in front