705 Loop Calibrator

705 Loop Calibrator

The Fluke 705 Loop Calibrator is a cost-effective, integrated solution for calibration, repair and maintenance of current loops. Feature-rich solution to loop calibration, maintenance and repair.

More Information
Features
  • A large display and simple, pushbutton interface for ease of use.

  • Simultaneous mA and % readout for quick, easy interpretation of readings.

  • mA accuracy of 0.02%

  • Push button 25% steps for fast, easy linearity checks. Save time over traditional 
    knob type controls.

  • "Span Check" for fast confirmation of zero and span.

  • Selectable slow ramp, fast ramp, and step to provide smooth outputs for valve slewing and loop functional tests.

  • 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.

  • Single 9V battery that is easily changed.

  • 0 - 20 mA or 4 - 20 mA default start up modes.

  • 3-year warranty.

Model 705 Loop Calibrator
Overview The Fluke 705 Loop Calibrator is a cost-effective, integrated solution for calibration, repair and maintenance of current loops. Feature-rich solution to loop calibration, maintenance and repair.
Includes The Fluke 705 Loop Calibrator is a cost-effective, integrated solution for calibration, repair and maintenance of current loops. Feature-rich solution to loop calibration, maintenance and repair.
Specifications
Specifications

Measurement

Range

Resolution

Accuracy

Voltage

0 to 28V DC

0.001V

0.025% of rdg + 1 LSD

Current

0 to 24mA

0.001mA

0.02% of rdg + 2 LSD

Current Sourcing Range

0 to 20mA or 4 to 20mA Note1.

0.001mA

0.025% of rdg + 2 LSD

Current Simulation

0 to 20mA or 4 to 20mA Note2.

0.025% of rdg + 2 LSD

Loop Power

24V while measuring mA

Maximum Voltage

30V

Display Current and % of Span

Yes

Auto Step, Auto Ramp

Yes

Span Check

Yes

General Specifications

Power Supply

9-volt Alkaline battery

Dimensions

152mm (L) x 70mm (W) x 41mm (D)

Weight

340g

Warranty

3-years

Specifications

Measurement

Range

Resolution

Accuracy

Voltage

0 to 28V DC

0.001V

0.025% of rdg + 1 LSD

Current

0 to 24mA

0.001mA

0.02% of rdg + 2 LSD

Current Sourcing Range

0 to 20mA or 4 to 20mA Note1.

0.001mA

0.025% of rdg + 2 LSD

Current Simulation

0 to 20mA or 4 to 20mA Note2.

0.025% of rdg + 2 LSD

Loop Power

24V while measuring mA

Maximum Voltage

30V

Display Current and % of Span

Yes

Auto Step, Auto Ramp

Yes

Span Check

Yes

General Specifications

Power Supply

9-volt Alkaline battery

Dimensions

152mm (L) x 70mm (W) x 41mm (D)

Weight

340g

Warranty

3-years

  • A large display and simple, pushbutton interface for ease of use.

  • Simultaneous mA and % readout for quick, easy interpretation of readings.

  • mA accuracy of 0.02%

  • Push button 25% steps for fast, easy linearity checks. Save time over traditional 
    knob type controls.

  • "Span Check" for fast confirmation of zero and span.

  • Selectable slow ramp, fast ramp, and step to provide smooth outputs for valve slewing and loop functional tests.

  • 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.

  • Single 9V battery that is easily changed.

  • 0 - 20 mA or 4 - 20 mA default start up modes.

  • 3-year warranty.