Fluke 353 AC/DC True-Rms 2000 Amp Clamp Meter

Confidently take reliable readings with the true-rms, Fluke 353 Clamp Meter; the tool of choice for high-current measurements up to 2000 Amps. The extra-wide jaw easily clamps around large conductors typically found in high current applications. The rugged design and CAT IV 600V, CAT III 1000V ratings, add an extra element of protection when taking high-powered measurements.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. This is a versatile tool for utilities, electrical contractors, and industrial service technicians.

Confidently take reliable readings with the true-rms, Fluke 353 Clamp Meter; the tool of choice for high-current measurements up to 2000 Amps. The extra-wide jaw easily clamps around large conductors typically found in high current applications. The rugged design and CAT IV 600V, CAT III 1000V ratings, add an extra element of protection when taking high-powered measurements.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. This is a versatile tool for utilities, electrical contractors, and industrial service technicians.

More Information
Features
  • Reliably handle a wide range of high-current applications with 
  • 2000A ac + dc true-rms, 1400A ac and 2000A dc.
  • The large 58mm (2.3 in) jaw capacity is suitable for large or multiple conductors.
  • In-rush current measurement captures 'power-on' surge current with accuracy and repeatability.
  • Accurately measure frequency up to 1kHz for optimum troubleshooting.
  • Quickly analyze readings using the MIN, MAX, and AVG functions.
  • A large backlight display allows for easy visibility in low-lit areas.
  • Use the display hold feature to capture readings even when the display cannot be viewed.
  • Use the low-pass filter to smooth out noisy loads and stabilize readings.
  • CAT IV 600V, CAT III 1000V rating for added user protection.
Model Fluke Model 353 AC/DC True-Rms 2000 Amp Clamp Meter
Specifications

Electrical Specifications

Current measurement DC and AC 10Hz to 100Hz

Range

Resolution

Accuracy

Trigger Level
for
Inrush

Trigger Level
for Hz
Filter OFF

Trigger Level
for Hz
Filter ON

40A

10mA

1.5% of rdg + 15 digits

0.50A

2.50A

0.50A

400A

100mA

1.5% of rdg + 5 digits

5.0A

2.5A

2.5A

2000A; 1400A AC rms

1A

1.5% of rdg + 5 digits

5A

8A

8A

 

Current measurement AC 100.1Hz to 1kHz

Range

Resolution

Accuracy

Trigger Level
for
Inrush

Trigger Level
for Hz
Filter OFF

Trigger Level
for Hz
Filter ON

40A

10mA

3.5% of rdg + 15 digits

0.50A

2.50A

0.50A

400A

100mA

3.5% of rdg + 5 digits

5.0A

2.5A

2.5A

2000A; 1400A AC rms

1A

3.5% of rdg + 5 digits

5A

8A

8A

 

Crest Factor 50/60Hz

Range

Crest Factor

40A

2 at 33A, 2.4 at 27A

400A

2 at 330A, 2.4 at 270A

2000A; 1400A AC rms

2 at 1000A, 2.4 at 833A

Add 2% to error spec for Crest Factor greater than 2

 

Frequency Measurement

Measurement Range

5.0Hz to 1kHz

Resolution

0.1Hz (15Hz to 399.9Hz); 1Hz (400Hz to 1kHz)

Accuracy - 5.0Hz to 100Hz

0.2% of rdg + 2 counts

Accuracy - 100.1Hz to 1kHz

0.5% of rdg + 5 counts

Trigger Level

Refer to current tables

 

Environmental Specifications

Operating Temperature

0°C to +50°C

Storage Temperature

-20ºC to +60ºC

Operating Humidity

0 to 95% non Condensing

EMI, RFI, EMC

FCC part 15, IEC/EN 61326-1:1997 Class B, IEC/EN 61326:1997 3V/m, performance
criteria B, EN 61325

Operating Altitude

2000 meters

Storage Altitude

10,000 meters

Drop Test Requirements

1 meter

Temperature Coefficients

0.1% of reading per ºC outside 22ºC to 24ºC

 

Safety Specifications

Overvoltage Category

600V CAT IV, 1000V CAT III

Safety Compliance

IEC 61010-2-032

IP Rating

42 (indoor use only)

 

General Specifications

Jaw Opening

58mm (2.28 ins)

Power Supply

Six 1.5V  type 'AA' NEDA 15A, or IEC LR6 Batteries

Battery Life (typical usage backlight off)

100 hours

Dimensions

300mm (L) x 98mm (W) x 52mm (D)

Weight

.814kg

Warranty

Two years

 

Ordering Information

Model Name

Description

Fluke 353

AC/DC True-Rms Clamp Meter, 2000A
Includes:
C43 soft carrying case, 6 type 'AA' batteries, and User's manual

Electrical Specifications

Current measurement DC and AC 10Hz to 100Hz

Range

Resolution

Accuracy

Trigger Level
for
Inrush

Trigger Level
for Hz
Filter OFF

Trigger Level
for Hz
Filter ON

40A

10mA

1.5% of rdg + 15 digits

0.50A

2.50A

0.50A

400A

100mA

1.5% of rdg + 5 digits

5.0A

2.5A

2.5A

2000A; 1400A AC rms

1A

1.5% of rdg + 5 digits

5A

8A

8A

 

Current measurement AC 100.1Hz to 1kHz

Range

Resolution

Accuracy

Trigger Level
for
Inrush

Trigger Level
for Hz
Filter OFF

Trigger Level
for Hz
Filter ON

40A

10mA

3.5% of rdg + 15 digits

0.50A

2.50A

0.50A

400A

100mA

3.5% of rdg + 5 digits

5.0A

2.5A

2.5A

2000A; 1400A AC rms

1A

3.5% of rdg + 5 digits

5A

8A

8A

 

Crest Factor 50/60Hz

Range

Crest Factor

40A

2 at 33A, 2.4 at 27A

400A

2 at 330A, 2.4 at 270A

2000A; 1400A AC rms

2 at 1000A, 2.4 at 833A

Add 2% to error spec for Crest Factor greater than 2

 

Frequency Measurement

Measurement Range

5.0Hz to 1kHz

Resolution

0.1Hz (15Hz to 399.9Hz); 1Hz (400Hz to 1kHz)

Accuracy - 5.0Hz to 100Hz

0.2% of rdg + 2 counts

Accuracy - 100.1Hz to 1kHz

0.5% of rdg + 5 counts

Trigger Level

Refer to current tables

 

Environmental Specifications

Operating Temperature

0°C to +50°C

Storage Temperature

-20ºC to +60ºC

Operating Humidity

0 to 95% non Condensing

EMI, RFI, EMC

FCC part 15, IEC/EN 61326-1:1997 Class B, IEC/EN 61326:1997 3V/m, performance
criteria B, EN 61325

Operating Altitude

2000 meters

Storage Altitude

10,000 meters

Drop Test Requirements

1 meter

Temperature Coefficients

0.1% of reading per ºC outside 22ºC to 24ºC

 

Safety Specifications

Overvoltage Category

600V CAT IV, 1000V CAT III

Safety Compliance

IEC 61010-2-032

IP Rating

42 (indoor use only)

 

General Specifications

Jaw Opening

58mm (2.28 ins)

Power Supply

Six 1.5V  type 'AA' NEDA 15A, or IEC LR6 Batteries

Battery Life (typical usage backlight off)

100 hours

Dimensions

300mm (L) x 98mm (W) x 52mm (D)

Weight

.814kg

Warranty

Two years

 

Ordering Information

Model Name

Description

Fluke 353

AC/DC True-Rms Clamp Meter, 2000A
Includes:
C43 soft carrying case, 6 type 'AA' batteries, and User's manual

  • Reliably handle a wide range of high-current applications with 
  • 2000A ac + dc true-rms, 1400A ac and 2000A dc.
  • The large 58mm (2.3 in) jaw capacity is suitable for large or multiple conductors.
  • In-rush current measurement captures 'power-on' surge current with accuracy and repeatability.
  • Accurately measure frequency up to 1kHz for optimum troubleshooting.
  • Quickly analyze readings using the MIN, MAX, and AVG functions.
  • A large backlight display allows for easy visibility in low-lit areas.
  • Use the display hold feature to capture readings even when the display cannot be viewed.
  • Use the low-pass filter to smooth out noisy loads and stabilize readings.
  • CAT IV 600V, CAT III 1000V rating for added user protection.