Fluke 324 AC/DC True-Rms Clamp Meter

Fluke is the undisputed leader in clamp meter technology, producing a line of tools that are as rugged and precise as they are easy to use. And with the introduction of the new Fluke 320 Series, the world's best clamp meter line just got better.

Developed for commercial, light industrial, HVAC, residential and DIY applications, the Fluke 323, 324 and 325 True-rms Clamp Meters combine functionality with value. With a smaller jaw and tapered design, these ergonomic clamp meters are extremely easy to use. They're Fluke tough, too, having been designed to withstand a one-meter drop. and they're Category IV rated.

Fluke is the undisputed leader in clamp meter technology, producing a line of tools that are as rugged and precise as they are easy to use. And with the introduction of the new Fluke 320 Series, the world's best clamp meter line just got better.

Developed for commercial, light industrial, HVAC, residential and DIY applications, the Fluke 323, 324 and 325 True-rms Clamp Meters combine functionality with value. With a smaller jaw and tapered design, these ergonomic clamp meters are extremely easy to use. They're Fluke tough, too, having been designed to withstand a one-meter drop. and they're Category IV rated.

More Information
Features
  • True-rms AC voltage and current for accurate measurements
    on non-linear signals.
  • 400A AC current measurement.
  • 600V AC and DC voltage measurement.
  • Resistance measurement up to 40kΩ also with continuity detection.
  • Temperature measurement.
  • Capacitance measurement.
  • Slim ergonomic design.
  • Large, easy to read backlight display.
  • Hold Function.
  • Includes Test leads, Soft carrying case and User's manual.
  • Two-year Warranty.
  • Cat IV 300V and CAT III 600V safety rating.
Model Fluke Model 324 AC/DC True-Rms Clamp Meter
Technical Specifications Measurement 1551A Ex 1552A Ex| Temperature Range -50°C to 160°C (-58°F to 320°F) -80°C to 300°C (-112°F to 572°F)| Temperature Resolution Selectable: 0.1°C, 0.01°C, 0.001°C default 0.01°C | Sample Rate Selectable: 0.5 sec, 1 sec, 2 sec, default 1 second | Accuracy (1-year) ±0.05°C (±0.09°F) | Display Units °C, °F | Sensor Type 100 Ohm thin-film RTD 100 Ohm wire-wound PRT | Sensor Length â
Safety Specifications EMC Compliance: EN 61326:2006 Annex C; CISPR II Edition 5.0-2009; Class B Enclosure Rating: IP50
General Specification Power Supply (DC only): 3 x type 'AAA' 1.5-volt Alkaline batteries | Battery Life: 300 hours (without LCD backlight) | Dimensions: 114mm (H) x 57mm (W) x 25mm (D) | Weight:196g
Environmental Specification Operating Temperature: -10°C to 50°C (14°F to 122°F) | Storage Temperature: -20°C to 60°C (-4°F to 140°F) | Humidity: 0% to 95% RH, non-condensing
Specifications

Technical Specifications

Measurement

Range

Accuracy

AC Current (True-Rms)

40.00A, 400.0A

1.5% of reading ±5 digits (45Hz to 400Hz)
Note: Add 2% for position sensitivity

AC Voltage (True-Rms)

600.0V

1.5% of reading ±5 digits

DC Voltage

600.0V

1.0% of reading ±5 digits

Resistance

400.0Ω, 4000Ω

1.0% of reading ±5 digits

Temperature

-10°C to 400.0°C

1.0% of reading ±8 digits (Resolution 0.1°C)

Continuity

≤ 30Ω

AC Response

True-Rms

Data Hold

Yes

Backlight Display

Yes

Note 1.: Temperature uncertainty (accuracy) does not include error of the thermocouple probe

 

Environmental Specifications

Operating Temperature

-10°C to +50°C

Storage Temperature

-30ºC to +60ºC

Operating Humidity

Non Condensing (≤ 10°C)

≤ 90% RH (at 10°C to 30°C)

≤ 75% RH (at 30°C to 40°C)

≤ 45% RH (at 40°C to 50°C)

EMI, EMC

Meets all applicable requirements in EN/IEC 61326-1

Operating Altitude

2000 meters

Storage Altitude

12,000 meters

Temperature Coefficients

Add 0.1 x specified accuracy for each ºC above 28ºC or below 18ºC

 

Safety Specifications

Overvoltage Category

CAT IV 300V, CAT III 600V

Safety Compliance

EN/IEC 61010-1 Pollution Degree 2

EN/IEC 61010-2-032

EN/IEC 61010-031:2002/A1:2008

CE

IP Rating

IP30 Per IEC 60529:2001 Non-operating

 

General Specifications

Jaw Opening

30mm (600MCM)

Power Supply

Two type 'AAA' NEDA 24A, IEC LR03 Batteries

Dimensions

207mm (L) x 75mm (W) x 34mm (H)

Weight

265g

Warranty

Two years

 

Ordering Information

Model Name

Description

Fluke 324

True-Rms Clamp Meter
Includes:
Test leads, Soft carrying case and User's manual

Technical Specifications

Measurement

Range

Accuracy

AC Current (True-Rms)

40.00A, 400.0A

1.5% of reading ±5 digits (45Hz to 400Hz)
Note: Add 2% for position sensitivity

AC Voltage (True-Rms)

600.0V

1.5% of reading ±5 digits

DC Voltage

600.0V

1.0% of reading ±5 digits

Resistance

400.0Ω, 4000Ω

1.0% of reading ±5 digits

Temperature

-10°C to 400.0°C

1.0% of reading ±8 digits (Resolution 0.1°C)

Continuity

≤ 30Ω

AC Response

True-Rms

Data Hold

Yes

Backlight Display

Yes

Note 1.: Temperature uncertainty (accuracy) does not include error of the thermocouple probe

 

Environmental Specifications

Operating Temperature

-10°C to +50°C

Storage Temperature

-30ºC to +60ºC

Operating Humidity

Non Condensing (≤ 10°C)

≤ 90% RH (at 10°C to 30°C)

≤ 75% RH (at 30°C to 40°C)

≤ 45% RH (at 40°C to 50°C)

EMI, EMC

Meets all applicable requirements in EN/IEC 61326-1

Operating Altitude

2000 meters

Storage Altitude

12,000 meters

Temperature Coefficients

Add 0.1 x specified accuracy for each ºC above 28ºC or below 18ºC

 

Safety Specifications

Overvoltage Category

CAT IV 300V, CAT III 600V

Safety Compliance

EN/IEC 61010-1 Pollution Degree 2

EN/IEC 61010-2-032

EN/IEC 61010-031:2002/A1:2008

CE

IP Rating

IP30 Per IEC 60529:2001 Non-operating

 

General Specifications

Jaw Opening

30mm (600MCM)

Power Supply

Two type 'AAA' NEDA 24A, IEC LR03 Batteries

Dimensions

207mm (L) x 75mm (W) x 34mm (H)

Weight

265g

Warranty

Two years

 

Ordering Information

Model Name

Description

Fluke 324

True-Rms Clamp Meter
Includes:
Test leads, Soft carrying case and User's manual

  • True-rms AC voltage and current for accurate measurements
    on non-linear signals.
  • 400A AC current measurement.
  • 600V AC and DC voltage measurement.
  • Resistance measurement up to 40kΩ also with continuity detection.
  • Temperature measurement.
  • Capacitance measurement.
  • Slim ergonomic design.
  • Large, easy to read backlight display.
  • Hold Function.
  • Includes Test leads, Soft carrying case and User's manual.
  • Two-year Warranty.
  • Cat IV 300V and CAT III 600V safety rating.